- Product Details
- {{item.text}}
Quick Details
-
Customized support:
-
Please inquire for details
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
GLC
-
Model Number:
-
GLC-DCFS-02
-
Operating Temperature:
-
-20~60
-
Product Name:
-
Remote Switch
-
Function:
-
Home Light Remote Switch
-
Material:
-
PC
-
Wireless Standard:
-
433 MHz
-
Max. Power:
-
12V≤350W 24V≤700W 36V≤1050W 48V≤1400W 60V≤1800W 72V≤2100W
-
Voltage:
-
DC 12V 24V 36V 48V 60V 72V
-
Usage:
-
Lamp Motor
-
Color:
-
White Black
-
Feature:
-
Water-proof
-
Brand:
-
GLC
-
Certification:
-
CE
Quick Details
-
Max. Current:
-
40A
-
Max. Voltage:
-
DC 12V 24V 36V 48V 60V 72V
-
Network:
-
RF
-
Customized support:
-
Please inquire for details
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
GLC
-
Model Number:
-
GLC-DCFS-02
-
Operating Temperature:
-
-20~60
-
Product Name:
-
Remote Switch
-
Function:
-
Home Light Remote Switch
-
Material:
-
PC
-
Wireless Standard:
-
433 MHz
-
Max. Power:
-
12V≤350W 24V≤700W 36V≤1050W 48V≤1400W 60V≤1800W 72V≤2100W
-
Voltage:
-
DC 12V 24V 36V 48V 60V 72V
-
Usage:
-
Lamp Motor
-
Color:
-
White Black
-
Feature:
-
Water-proof
-
Brand:
-
GLC
-
Certification:
-
CE
Product features:
1. IP55 dustproof and waterproof: suitable for indoor and outdoor
2. Wide voltage: DC12V-72V voltage range can be used
3. High
power: 40A
4. Work mode support: self-locking, interlocking, manual opening and closing
5. A receiver can be paired with 32 remote controllers, independently coded, without interfering with each other
6. Two colors: black and white
7. Stable performance, mature quality, manufacturer's private model, support customization
Scope of application: water pumps, motors, lamps, industrial control equipment, etc.
Product Paramenters
Key word
|
remote control switch
|
Working voltage
|
DC 12V 24V 36V 48V 60V 72V
|
|
|||
Receiver Size
|
81*51*34mm
|
Working frequency
|
433.932 MHz
|
|
|||
Emission current
|
≤0.01 uA
|
Remote distance
|
50m~100m
|
|
|||
Remote control size
|
12*29*61mm
|
Remote control battery
|
CR2016 two in series
|
|
|||
Current
|
40A
|
|
|
|
|||
Working mode
|
Self-locking Interlock Manual on and off
|
|
|
|
voltage
|
12v
|
24v
|
36v
|
48v
|
60v
|
72v
|
Load power
|
350W
|
700W
|
1050W
|
1140W
|
1800W
|
2100W
|
Details Images
Installation Instructions
product assortment
Learn Matching Instructions
Work mode introduction
Self-locking mode:
Use a button to control, press once to open, and then press again to close, which is called self-locking.
Interlocking mode: When the remote control has two buttons, one button is on and the other button is off, which is called interlock.
Inching mode: Without a remote control, press the learn button on the receiver, press once to turn on, and then press to turn off.
Interlocking mode: When the remote control has two buttons, one button is on and the other button is off, which is called interlock.
Inching mode: Without a remote control, press the learn button on the receiver, press once to turn on, and then press to turn off.
Pairing method
Self-locking:
The controller is powered on, press and hold the learning button for 3 seconds, the indicator light will flash once,release your hand, press the button of the remote control, the indicator light will flash 3 times, indicating successful code matching
Interlock: The controller is powered on, press and hold the learning button for 5 seconds, the indicator light flashes 2 times,release your hand, press the ON/ON button of the remote control, the indicator light is on after 3 flashes Status, and then press the OFF/ key of the remote control, the indicator light flashes twice, indicating that the code is successfully coded
Clear code: The controller is powered on, press and hold the learning button and wait for 8 seconds, the indicator light flashes 4 times, indicating that the clear code is successful
Manual on and off: the learning button on the controller can control the output on and off, press it to turn it on, and press it to turn it off
Interlock: The controller is powered on, press and hold the learning button for 5 seconds, the indicator light flashes 2 times,release your hand, press the ON/ON button of the remote control, the indicator light is on after 3 flashes Status, and then press the OFF/ key of the remote control, the indicator light flashes twice, indicating that the code is successfully coded
Clear code: The controller is powered on, press and hold the learning button and wait for 8 seconds, the indicator light flashes 4 times, indicating that the clear code is successful
Manual on and off: the learning button on the controller can control the output on and off, press it to turn it on, and press it to turn it off
FAQ
Q1 Are you a factory or a trading company
A1: We are a factory.
A1: We are a factory.
Q2: What is the mode of transportation?
A2: DHL/UPS/TNT/ FedEx and other air and sea freight are available.
Q3: How many remote controls can a receiver pair with?
A3: A receiver can pair up to 32 remote controls.
Q4: I need multiple remote controls to run. Will they interfere with each other?
A4: Each set of products is independently paired and does not interfere with each other. However, it should be avoided to press the remote control at the same time with an interval of one to two seconds
A2: DHL/UPS/TNT/ FedEx and other air and sea freight are available.
Q3: How many remote controls can a receiver pair with?
A3: A receiver can pair up to 32 remote controls.
Q4: I need multiple remote controls to run. Will they interfere with each other?
A4: Each set of products is independently paired and does not interfere with each other. However, it should be avoided to press the remote control at the same time with an interval of one to two seconds
Q5: Can I work in wet areas?
A5: It is not recommended to work in humid environment.
Q6: What is the remote control distance?
A6: 50m~100m, 500m~1000m, 3000m ~5000m can be selected
A5: It is not recommended to work in humid environment.
Q6: What is the remote control distance?
A6: 50m~100m, 500m~1000m, 3000m ~5000m can be selected
Q7:
What should I do when the controller's power is fine, but the remote control doesn't work on and off?
A7:This situation may be due to code drop, the solution is: first clear code, and then follow the required mode of learning. (See thedetails page for learning methods)
A7:This situation may be due to code drop, the solution is: first clear code, and then follow the required mode of learning. (See thedetails page for learning methods)
Hot Searches