- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
Rehow
-
Body Material:
-
HIgh Quality Sturdy Steel
-
Refrigerant:
-
R22, R134A, R404A, R502, R507C, R407C
-
Max.working pressure:
-
30Bar
-
Max.testing pressure:
-
3600Kpa
-
Medium temperature:
-
-40~+120℃
Quick Details
-
Type:
-
Accumulator
-
Application:
-
Refrigeration Parts
-
Place of Origin:
-
Zhejiang, China
-
Brand Name:
-
Rehow
-
Body Material:
-
HIgh Quality Sturdy Steel
-
Refrigerant:
-
R22, R134A, R404A, R502, R507C, R407C
-
Max.working pressure:
-
30Bar
-
Max.testing pressure:
-
3600Kpa
-
Medium temperature:
-
-40~+120℃
Product Overview
Refrigeration heat exchanger suction line accumulator
Product Introduction
In air-conditioning refrigeration system, there’re high pressure and low pressure refrigerant pipes. High pressure refrigerant has high temperature and needs condenser cooling, and the low pressure refrigerant flow from evaporator needs suction line accumulator to separate gas and liquid, the liquid needs time and temperature to evaporate to gas and then enter compressor, it avoids liquid compression to prolong compressor’s life.
In air-conditioning refrigeration system, there’re high pressure and low pressure refrigerant pipes. High pressure refrigerant has high temperature and needs condenser cooling, and the low pressure refrigerant flow from evaporator needs suction line accumulator to separate gas and liquid, the liquid needs time and temperature to evaporate to gas and then enter compressor, it avoids liquid compression to prolong compressor’s life.
The heat exchange suction accumulator puts two refrigerant pipes together to one vessel, one is high pressure and high temperature and needs cooling, the other is low pressure and low temperature and require to evaporate, so that the two pipes can transfer high and low temperature, let the high temperature refrigerant get cooling and low temperature refrigerant get evaporated. The system’s efficiency will be promoted greatly and cooling effect get better after the heat exchanger.
Basic Information
Suction Accumulators protect compressors from liquid slugging.
* Solid copper connections;
* Corrosion resistant epoxy powder paint finish;
* Inlet deflector that directs refrigerant flow to prevent internal splashing and aid in the collection of refrigerant oil;
* Used with CFC, HCFC, and HFC refrigerants;
* Available for systems through 28 tons nominal capacity.
* Solid copper connections;
* Corrosion resistant epoxy powder paint finish;
* Inlet deflector that directs refrigerant flow to prevent internal splashing and aid in the collection of refrigerant oil;
* Used with CFC, HCFC, and HFC refrigerants;
* Available for systems through 28 tons nominal capacity.
* If the refrigeration system’s evaporation temperature below-15℃,we recommend to assemble one heat exchanger.
Features
* Fusible plug on larger diameter units
* Solid copper connections
* Corrosion resistant epoxy powder paint finish
* Inlet deflector directs refrigerant flow to prevent internal
* Splashing and aid in the collection of refrigerant oil
* Maximum working pressure: 300 psig
* Fusible plug temperature: 430°F
* Fusible plug temperature: 430°F



PRODUCT SPECIFICATIONS
Item
|
Refrigerant heat exchanger suction accumulator
|
Refrigeration Oil
|
R22/R134A/R404A/R407C/R502/R507
|
Max.Working Pressure
|
3000kpa
|
Max.Testing Pressure
|
3600kpa
|