Products
Combined Kjeldahl Protein Nitrogen Automatic Kjeldahl Digestion and Distillation Unit
Combined Kjeldahl Protein Nitrogen Automatic Kjeldahl Digestion and Distillation Unit
Combined Kjeldahl Protein Nitrogen Automatic Kjeldahl Digestion and Distillation Unit
Combined Kjeldahl Protein Nitrogen Automatic Kjeldahl Digestion and Distillation Unit
Combined Kjeldahl Protein Nitrogen Automatic Kjeldahl Digestion and Distillation Unit
Combined Kjeldahl Protein Nitrogen Automatic Kjeldahl Digestion and Distillation Unit
Combined Kjeldahl Protein Nitrogen Automatic Kjeldahl Digestion and Distillation Unit
Combined Kjeldahl Protein Nitrogen Automatic Kjeldahl Digestion and Distillation Unit

Combined Kjeldahl Protein Nitrogen Automatic Kjeldahl Digestion and Distillation Unit

FOB Reference Price: Get Latest Price
≥1 Sets
US $9500
Free Inquiry
Customized Request
  • Product Details
  • {{item.text}}

Quick Details

Brand Name:
Bonnin Instrument
Model Number:
KN2200F
Equipment name:
Kjeldahl Method Nitrogen Tester
Heating method:
Infrared heating and high-purity graphite conduction
Digestion tube capacity:
300ml
DSC display:
0.001 mW
Certification:
ISO, CE
Power supply:
110V/220V 50Hz
Warranty Time:
12 months

Quick Details

Warranty:
1 Year
Power:
Electronic
Place of Origin:
Hubei, China
Brand Name:
Bonnin Instrument
Model Number:
KN2200F
Equipment name:
Kjeldahl Method Nitrogen Tester
Heating method:
Infrared heating and high-purity graphite conduction
Digestion tube capacity:
300ml
DSC display:
0.001 mW
Certification:
ISO, CE
Power supply:
110V/220V 50Hz
Warranty Time:
12 months
Product Description

Applications

The fully automated Kjeldahl nitrogen analyzer consists of four basic components: (1) distillation unit; (2) titration device; (3) detection device; and (4) waste disposal device.

Characteristics

1. Automatic completion of distillation, titration,calculation, printing, waste discharge;

2. Built-in colorimetric titration device;

3. Two steam models, can adjust solutions adding sequence, for distillation and absorption special samples;

4. Built-in printer, USB and series port for data outlet,

5. Samples’ methods can be edited and store;

6. Solutions adding are quantified;

7. Multi protection, safety door, tube position, cooling water testing, etc;

8. Self-trouble shooting functions for valves, pumps and sensors;

9. Tube and pips automatic emptying;

Technical datas

KN2200F Fully Automated Kjeldahl Nitrogen Analyzer

Measure range

0.1mg  –  200mg

Analysis time

5 – 10min

Recovery

≥99.5%

Samples available

Solid ≤ 5g; Liquid ≤20ml

Burette accurate

1.0μL/ step

Reproducibility

±0.5%

Functions List

Comparison

Variable steam generator

YES

Cooling water pressure monitor

YES

Cooling water temperature monitor

YES

Automatic alkali solution adding

YES

Automatic dilute water

YES

Auto receiver solution adding

YES

Tube emptying

YES

Removable drain tray

YES

Safety door

YES

Tube on position sensor

YES

Tube replacement  sensor

YES

Colorimetric titration device

YES

Results calculation

YES

Result and data storing

YES

Built-in printer

YES

Automatic washing tube and pips

YES

Trouble shooting self-detecting functions

YES

Sample determination
1.1 Weighing
The milk sample needs to be mixed and sampled. Because the milk sample is easy to float up and is directly sampled from the upper layer without mixing, the measurement result will be low. The milk powder sample is evenly mixed and weighed with a weighing paper and sent to the bottom of the digestive tract with tweezers. The sample remaining on the tube wall due to improper operation is flushed into the bottom of the digestive tube with sulfuric acid when sulfuric acid is added. If it remains on the pipe wall without flushing with sulfuric acid, the measurement result will be lowered.

1.2 Digestion
In the process of adding acid, the influence of the composition of the sample on the amount of acid consumed should be considered. The amount of acid is small, the sample is incompletely digested, and the measurement result is low; the amount of acid is large, and the acid is excessively mixed with the alkali in the process of the machine, and the free amine cannot be distilled out, which seriously affects the measurement result.
During digestion, pre-digestion was first carried out at 220 ° C for 1 hour and then the temperature was raised to 420 ° C. The purpose of pre-digestion is to allow the sample to react slowly with sulfuric acid. Without pre-digestion, concentrated sulfuric acid will react violently with the sample at high temperature, causing carbonization, and the measurement result will be low. The particles caused by carbonization will also block the pipeline during the waste discharge process, resulting in the instrument not working properly.