Quick Details
-
Brand Name:
-
KELISAIKE/OEM, KELISAIKE
-
Model Number:
-
WTQY800B
-
Power supply:
-
220V AC/50Hz 100W
-
Ambient temperature:
-
5℃~+45℃
-
Application:
-
Petrochemical industry;electronics industry; organic solvent
-
Analog Interface:
-
-wire 4-20mA output, 2-wire 4-20mA output
-
Communication:
-
1-way RS-232, 1-way RS-485(Support Mod-bus protocol)
-
Protection Grade:
-
IP42
-
Detection principle:
-
Ultraviolet light
-
Sampling method:
-
Condensation sampling
Quick Details
-
Type:
-
online gas analyzer
-
Warranty:
-
1year, 12 Months
-
Place of Origin:
-
Jiangsu, China
-
Brand Name:
-
KELISAIKE/OEM, KELISAIKE
-
Model Number:
-
WTQY800B
-
Power supply:
-
220V AC/50Hz 100W
-
Ambient temperature:
-
5℃~+45℃
-
Application:
-
Petrochemical industry;electronics industry; organic solvent
-
Analog Interface:
-
-wire 4-20mA output, 2-wire 4-20mA output
-
Communication:
-
1-way RS-232, 1-way RS-485(Support Mod-bus protocol)
-
Protection Grade:
-
IP42
-
Detection principle:
-
Ultraviolet light
-
Sampling method:
-
Condensation sampling
Flue gas (CEMS) emission continuous on-line monitoring system
Flue gas continuous monitoring system(CEMS) (Hereafter called system) can automatically monitor SO2, NO, CO, O2, dust, flue gas flow and pressure, temperature and so on. The system can be flexible and optimized configuration based on the specific conditions of the site parameters and technical requirements, can be measurement for gaseous substances, dust and other in the continuous flue gas emission, to achieve the quantitative control of flue gas emissions.
a) In accordance with the complete system requirements, adopt analysis cabinet structure, complete the " Engineer, Procure and Construct design", simplified installation and commissioning.
b) Adopt imported high-performance membrane pump configuration, the pump with strong anti-corrosion ability, high reliability, long service life, small maintenance workload, reliable operation.
c) The device pretreatment system uses a special structural design, using two dehumidification, three dust elimination, combined with the purification method of coarse filtration and fine filtration, dehumidification and acid fog elimination, in long-term operation shows the effective solution to the high dust, high humidity and sulfur conditions, big maintenance workload, low online continuous operation rate. Stable and reliable performance, small maintenance workload.
d) The device uses dry process, extract the sampling style, pulse cleaning, sampling tube electric heating, program control and other technology, with automatic sampling, continuous operation, control interlock and other functions
Apply to on-line continuous automatic analysis to monitor the SO2, NO, CO, O2, dust, flow, temperature, pressure, etc. in the flue gas pipeline of various industrial boilers, kiln and heating furnace, adjust the best air to fuel ratio according to the analysis results, improve combustion efficiency, to achieve energy conservation and reduce environmental pollution. Therefore, the system is widely used in thermal power plants, metallurgy, petrochemical, building materials and other industries.
Project |
Indicators |
SO2 Detection range |
Min:0-50ppm,Max:0-100%, |
NO Detection range |
Min:0-50ppm,Max:0-100%, |
O2 Detection range |
0-25%, Electrochemical or zirconia |
Linearity error |
≤±1%F.S. |
Repeatability |
≤1% |
Zero drift |
≤±1%F.S./ week |
Span drift |
≤±1%F.S./week |
Ambient temperature |
5℃~45℃ |
Response time(T90) |
<10s |
Size |
19 ” *3U*320mm |
Analog interface |
3-way 4-20mA output,2-way 4-20mA output |
Data interface |
4-way switch input; 8-way relay output |
Communication Interface |
1-way RS-232,1-way RS-485(Supports Mod-bus protocol) |
Power |
220VAC/50Hz 100W |
Protection grade |
IP42 |
Sample gas input and output interface |
Ø6 Tube Fittings |
- Analyzer uses the following optical technology platform to get the UV absorption spectrum, the technology platform consists of light source, gas chamber, fiber optics and spectroscopy (including the diaphragm, holographic gratings, linear array detector) and other optical components.
- UV-visible light emitted by the optical window into the gas chamber, is absorbed by the sample gas flowing through the measured gas chamber, carrying the tested sample gas absorbs light through the lens after gathering information coupled into optical fiber through the optical fiber transmission into the spectrometer splitting, sampling, to obtain the absorption spectrum of the gas.
- use DOAS technology spectrum analysis, can analyze the concentration of the gas in the relevant component.
>>>OEM
Customize producta are also available,pls feel free to contact me for more detailes.