Karl Fischer oil moisture analyzer/ASTM D6304  Oil Trace Moisture Tester
Karl Fischer oil moisture analyzer/ASTM D6304  Oil Trace Moisture Tester

Karl Fischer oil moisture analyzer/ASTM D6304 Oil Trace Moisture Tester

FOB Reference Price: Get Latest Price
≥1 Sets
US $2000
Free Inquiry
Customized Request
  • Product Details
  • {{item.text}}

Quick Details

Brand Name:
yucai
Model Number:
KR-103B

Quick Details

Warranty:
1 Year
Power:
Electronic
Place of Origin:
Shanghai, China
Brand Name:
yucai
Model Number:
KR-103B
Product Overview

Oil Content Tester in Petroleum Wax

The KR-103B model karl fischer oil moistrue tester uses the classical water measurement method [Karl-Fescher Coulomb electricity method], which can quickly analyze the liquid with water content in the range of 0.0001% (1ppm) to 100% in one minute, in liquid,gas and solid. The moisture in the sample of gas is widely used in chemical, petroleum, electric power, scientific research,railway and other industries.
润滑脂工作后放在转鼓试验机上,判断润滑脂的机械剪切安定性。 KR-WL 60油脂泄漏试验机严格按照ASTMD 1263和SH/T0326标准设计制造。
FEATURES AT A GLANCE
Features:
1. This instrument adopts microprocessor automatic intelligent analysis and measurement.
2. 10 inch 65K color touch LCD screen (resolution 800 * 600 pixels) display.
3. The surface is treated by electrostatic spray, anti-corrosion and easy to clean.
4. Practical auxiliary function, can be connected to “electronic balance” and instrument data communication and processing;(optional).
5. The blank current microprocessor automatically controls the compensation, and the reagent can quickly reach the equilibrium state.
6. 0-430 mA large electrolysis current, high detection sensitivity and fast analysis speed.
7. Large storage function, the measurement result is automatically stored in 1000, and the history is checked at any time.
8. The instrument automatically determines the sample and the analysis result is automatically displayed, which can automatically calculate the average value of the sample multiple times.
9. Automatically calculate and print ug / ppm / percentage / mg / L / sample name /
Standards compliant:
GB/T 6283-2008 Determination of moisture content in chemical products - Karl Fischer method.
ASTM E1064-2008 Karl Fischer Coulometric Titration for Determination of Water Content in Organic Liquids.
GB/T 7600-1987 Determination of moisture content of transformer oil during operation (Coulomb method).
ASTM D4928-00 (2010) Karl Fischer Coulometric Titration for Determination of Water Content in Crude Oil.
ASTM D6304-2007 Karl Fischer Coulometric Titration for Determination of Water Content in Petroleum Products, Lubricating Oils and Additives.
ISO 10337-1997 Determination of moisture content of crude oils Karl Fischer Coulometric titration.
GB/T 11146-2009 Determination of crude oil water content Karl Fischer Coulometric titration.
GB/T 3727-2003 Determination of trace water in ethylene and propylene for industrial use.
GB/T 5074-1985 Microcoulometric method for determination of moisture content of coking products.
GB/T 6023-2008 Determination of trace water in industrial butadiene Karl Fischer Coulometric.
GB/T 7376-2008 Determination of trace moisture in industrial fluoroalkanes - Karl Fischer method.
GB/T 18619.1-2002 Determination of water content in natural gas - Karl Fischer Coulomb method.
GB/T 18826-2002 Industrial 1,1,1,2-tetrafluoroethane HFC-134a.
SH/T 0246-1992 Determination of water content in light petroleum products (electricity method).
SH/T 0255-1992 Additives and additives containing lubricants - Determination of moisture (electricity method).
ASTM E1064-2008 Karl Fischer Coulometric Titration for Determination of Water Content in Organic Liquids.
ASTM D4928-00 (2010) Karl Fischer Coulometric Titration for Determination of Water Content in Crude Oil.
ASTM D6304-2007 Karl Fischer Coulometric Titration for the determination of water content in petroleum products, lubricants and additives.
10. 本体四周用保温棉包裹。

PRODUCT SPECIFICATIONS
NO
Item
Data
1
Method of Display
10 inch 65K color touch LCD (resolution 800*600 pixels) display
2
Method of Testing
microprocessor controlled electrolysis (Karl-Fescher Coulomb method)
3
Rate of Electrolysis
2.4 mg H2O/min
4
Electrolysis Current
0-430 mA automatic control
5
Testing Range
0.01ug H2O-200mg H2O
6
Water Content Range
0.0001%(1ppm)—100%
7
Sensitivity
0.01ug H2O
8
Accuracy
When the water content is 100 μg water-1000 μg, the error is ≤±3 ug, and when the water content is above 1000 μg water, the error
is ≤±0.2% (without injection error)
9
Drift Compensation
microprocessor automatic control
10
Stirring Speed
adjustable control
End-point Indication
screen display / printout / audible warning / end point indicator
Data Input
Input via touch screen
Sample Number
user-defined
Calendar/Clock
Analyze time, date display and printout
Self-checking
automatic diagnosis of instrument failure
Special Function
can be connected to laptops and other computers, can work online or independently
Storage function
1000
Power Consumption
40W
Dimension
360×310×135mm
Working Environment
Temperature: 5℃-40℃,Humidity: <85%
Power Supply
AC220V±10% 50HZ±2.5HZ
Weight
About 6kg