- Product Details
- {{item.text}}
Quick Details
-
Application:
-
Exterior
-
Design Style:
-
Traditional
-
Place of Origin:
-
Hebei, China
-
Brand Name:
-
UNITED INSULATION
-
Model Number:
-
UET EXWR120100
-
Material:
-
Rock wool
-
Density:
-
120kg/m3
-
Thickness:
-
100mm
-
Width:
-
600mm
-
Length:
-
1200mm
-
Average NRC:
-
1.05
-
Thermal Conductivity:
-
0.032W/mk
-
Compression Strength (kPa):
-
90
-
Tensile Strength (kPa):
-
130
-
Fire Performance:
-
A1
-
Certificate:
-
FM/ASTM/ISO
Quick Details
-
Warranty:
-
More than 5 years
-
After-sale Service:
-
Online technical support, Onsite Installation, Onsite Training, Onsite Inspection, Free spare parts, Return and Replacement
-
Project Solution Capability:
-
graphic design, total solution for projects, Cross Categories Consolidation
-
Application:
-
Exterior
-
Design Style:
-
Traditional
-
Place of Origin:
-
Hebei, China
-
Brand Name:
-
UNITED INSULATION
-
Model Number:
-
UET EXWR120100
-
Material:
-
Rock wool
-
Density:
-
120kg/m3
-
Thickness:
-
100mm
-
Width:
-
600mm
-
Length:
-
1200mm
-
Average NRC:
-
1.05
-
Thermal Conductivity:
-
0.032W/mk
-
Compression Strength (kPa):
-
90
-
Tensile Strength (kPa):
-
130
-
Fire Performance:
-
A1
-
Certificate:
-
FM/ASTM/ISO
PRODUCT INFORMATION
UET external wall fire stoping rock wool slab is a lightweight, semi-rigid or rigid stone wool insulation that provides superior fire resistance and sound control. UET-ROOF rock wool slab is FM and Intertek approved as a forming material for numerous firestop systems. This product is designed to fill perimeter gaps between concrete floor slabs and exterior wall systems, between firewalls and ceiling slabs, and around conduit pipes and duct openings through walls and floor slabs.
AVAILABLE FORMS
Semi-Rigid or Rigid Board
AVAILABLE SIZE
Product Code |
Density
(kg/m³) |
Thickness
(mm) |
Width
(mm) |
Length
(mm) |
Packing
(pcs/PKG) |
PKG/40'HQ
(No#) |
|
UET FSR 12075-200 | 120 | 75-200 | 600 | 1200 | 2-5 |
Loading Qty,
Please consult |
|
UET FSR 15075-150 | 150 | 75-150 | 600 | 1200 | 2-5 | ||
UET FSR 18075-120 | 180 | 75-120 | 600 | 1200 | 2-5 |
Consult your local sales representative for other available sizes and specification
PHYSICAL PROPERTIES OF UET FSR 120100
Tested Content | Tested Method | Tested Method | |
Density | 120kg/m³ | GB/T 5480.3 | |
Thickness | 100mm | GB/T 5480.3 | |
Thermal Conductivity (W/m·K) | 0.036 | ASTM C518 (C177) | |
Average NRC | 1.05 | ASTM C423 | |
Maximum Service Temperature | 750°C | GB/T 17430, GB50264 | |
Recommended Service Temperature | 650°C | ASTM C411-05, ASTM C447-03, GB50264 | |
Compression Strength (kPa) | 90 | EN 826 | |
Tensile Strength (kPa) | 130 | EN 1607 | |
Shear Strength (kPa) | 65 | EN 12090 | |
Non-Combustibility | |||
Flame Diffustivity | 50 | ASTM E84-10 | |
Flame Propagation | 25 | ASTM E84-10 | |
Fire Performance | Class A1 | GB 8624, EN13501-1, BS 476 Part4 | |
Water Vapor Sorption (% by Weight) | ≤1% | ASTM C1104/1104M | |
Water Vapor Sorption (% by Volume) | ≤1% | ASTM C1104/1104M | |
Water Repellency (Option available) | >99% | GB/T 10299 |
STORAGE AND TRANSPORT
Store flat. Handle with care, especially on the edges and corners, which can be damaged if subject to sharp or heavy impact.
QUALITY MANAGEMENT AND SPECIFICATION COMPLIANCE
ISO 9001: 2008, ISO 14001:2004
GB/T 17430, GB50264, ASTM C411, ASTM C447-03, ASTM C423, GB50264
GB/T 17430, GB50264, ASTM C411, ASTM C447-03, ASTM C423, GB50264
FIRE PERFORMANCE
Classified as Euroclass A1 to STN EN 13501-1: 2007 and FM Certificate
FEATURES AND BENEFITS
• Natural inorganic material
• Class A fire resistance
• Great moisture resistance
• Excellent mod resistance, good chemical stability
• Aging resistance, and corrosion resistance
• Class A fire resistance
• Great moisture resistance
• Excellent mod resistance, good chemical stability
• Aging resistance, and corrosion resistance
Keep Cool | Keep Warm | Fire Proof | Moisture Proof | Noise Control | Sustainbility | Save Cost | Health Safe |
APPLICATIONS
It is used for filling perimeter gaps between concrete floor slabs and exterior wall systems, between firewalls and ceiling slabs, and around conduit pipes and duct openings through walls and floor slab.
NOTICE
Safety first. Follow good safety/industrial hygiene practices during insulation. Wear appropriate personal protective equipment. Read SDS and literature before specification and insulation.
STANDARD & CERTIFICATE APPROVED PRODUCT
UNITED PEOPLE SERVE THE WORLD
Hot Searches