Products
Pdu Power Distribution Unit Cabinet Electrical Control Panel Box, Electrical Distribution Board Manufacturers
Pdu Power Distribution Unit Cabinet Electrical Control Panel Box, Electrical Distribution Board Manufacturers
Pdu Power Distribution Unit Cabinet Electrical Control Panel Box, Electrical Distribution Board Manufacturers
Pdu Power Distribution Unit Cabinet Electrical Control Panel Box, Electrical Distribution Board Manufacturers
Pdu Power Distribution Unit Cabinet Electrical Control Panel Box, Electrical Distribution Board Manufacturers
Pdu Power Distribution Unit Cabinet Electrical Control Panel Box, Electrical Distribution Board Manufacturers
Pdu Power Distribution Unit Cabinet Electrical Control Panel Box, Electrical Distribution Board Manufacturers
Pdu Power Distribution Unit Cabinet Electrical Control Panel Box, Electrical Distribution Board Manufacturers

Pdu Power Distribution Unit Cabinet Electrical Control Panel Box, Electrical Distribution Board Manufacturers

FOB Reference Price: Get Latest Price
≥1 Pieces
US $3000
Free Inquiry
Customized Request
  • Product Details
  • {{item.text}}

Quick Details

Input Voltage:
220/380v, TN-S system
Frequency:
50/60Hz±10%
Output Voltage:
220V(1Ph+N+PE);380V(3Ph+N+PE)
Capacity:
10~630A
SPD:
Standard C-level surge protection: 20KA, 40KA
Display:
Standard 7-inch touch screen, optional 10 inch or above
Communication interface 1:
One way RS485 Modbus-RTU
Communication interface 2:
One way RJ45 10/100m, TCP/IP Modbus Protocol (optional)
Dimension:
600/800(W)*1000/1100/1200(D)*2000/2200(H)mm

Quick Details

Place of Origin:
Zhejiang, China
Brand Name:
ZTMM
Color:
Black, Black
Input Voltage:
220/380v, TN-S system
Frequency:
50/60Hz±10%
Output Voltage:
220V(1Ph+N+PE);380V(3Ph+N+PE)
Capacity:
10~630A
SPD:
Standard C-level surge protection: 20KA, 40KA
Display:
Standard 7-inch touch screen, optional 10 inch or above
Communication interface 1:
One way RS485 Modbus-RTU
Communication interface 2:
One way RJ45 10/100m, TCP/IP Modbus Protocol (optional)
Dimension:
600/800(W)*1000/1100/1200(D)*2000/2200(H)mm
Products Description

High availability

1.Novel and elegant appearance 2.The rack color and style can be customized according to the use environment 3.Support single-sided single main road, single-sided double main road and double-sided double main road layout 4.Flexible incoming and outgoing modes 5.The setting of maintenance surface is flexible and convenient for inspection and maintenance.

Fully enclosed structure and modular design

1.Each functional module is isolated from each other to prevent the operator from directly contacting the bus and prevent foreign matters from contacting the electrical device 2.Protection : IP40 3.All systems comply with the existing national and international standards and specifications, and the components of the products have passed strict quality certification

High integration and performance

1. Advanced DSP full digital control makes the protection system control faster, more accurate and more stable, and comprehensively improves the reliability. 2. The anti-interference ability is enhanced to avoid the inherent hardware parameter drift and other defects of the analog controller and ensure the product consistency. 3. High integration and simplified circuit. 4. Good performance and highly integrated products ensure more stable and safe operation of the equipment.

Comprehensive power quality monitoring

It can monitor complete power quality parameter information and provide key data 1.Main circuit measurement parameters include but are not limited to three phase voltage, current, frequency, active power, reactive power, power factor, active electric energy, reactive electric energy, zero ground voltage, neutral line current, total harmonic content (THD), 2nd-63rd harmonic, current voltage unbalance, current K factor (KF), voltage crest factor (CF), telephone waveform factor (thff), peak voltage, voltage and current sequence, ambient temperature and humidity. 2.Branch measurement parameters include but are not limited to voltage, current, frequency, active power, reactive power, power factor, active electric energy, reactive electric energy, 2-31 harmonics

Intelligent management

1.Effective analysis of all power parameters 2.Equipment level energy efficiency management 3.Touch screen visualization 4.Effective management and risk early warning of key data of each loop 5.Provide standardized interfaces to easily connect with third-party systems 6.Provide a variety of alarm modes for fault early warning It is necessary to support the access to the energy management platform to form energy consumption classification, sub item and sub regional statistical analysis for the energy consumption and operation information of the data center, so as to realize the visualization of energy management, find out the blind spots of energy consumption, tap the energy-saving potential, and help customers optimize the use of energy.
Name
Quantity ( PCS )
Input Voltage
220/380v, TN-S system 1
Frequency
50/60Hz±10% 2
Output Voltage
220V(1Ph+N+PE);380V(3Ph+N+PE) 4
Capacity
10~630A
Distribution Architecture
Support single bus, double bus and multi bus systems
Branch air switch supports fixed switch, hot plug air switch or hot plug adjustable phase air switch
System Function
three phase voltage, current, frequency, active power, reactive power, power factor, active electric energy, reactive electric energy, zero ground voltage, neutral line current, total harmonic content (THD), 2nd-63rd harmonic, current voltage unbalance, current K factor (KF), voltage crest factor (CF), telephone waveform factor (thff), peak voltage, voltage and current sequence, ambient temperature and humidity
voltage, current, frequency, active power, reactive power, power factor, active electric energy, reactive electric energy, 2-31 harmonics
Accuracy
Incoming line: voltage / current level 0.2, active power / electric energy level 0.5s, reactive power / electric energy level 1
Outgoing line: voltage / current level 0.5, active power / active electric energy / reactive power / reactive electric energy level 1
SPD
Standard C-level surge protection: 20KA, 40KA
Display
Standard 7-inch touch screen, optional 10 inch or above
Communication interface
One way RS485 Modbus-RTU
One way RJ45 10/100m, TCP/IP Modbus Protocol (optional)
Dimension
600/800(W)*1000/1100/1200(D)*2000/2200(H)mm
Accessories
More Products
Our Advantage
About Us
Certificate
Packaging&Transport
FAQ
Q: Can I get some samples ?
A: Yes, Samples are 30% off the price of normal products, and material samples are free of charge.
Q: Could I use my own LOGO or design on goods ?
A: Yes,we can customized the LOGO according to your requests. Specific details please contact us.
Q: Can I choose the colors?
A: Yes, Customized color is available.
Q: What is the delivery time ?
A: A week for samples, 35 days for mass production after receiving the deposit.
Q: What is the payment team ?
A: T/T, L/C at sight.
Q: May I visit your factory?
A: Sure, Welcome any time.we can also pick you up at the airport or station.
Q:Why choose us?
A: We have the strict system for production, regarding the quality as our life. We do the best to every customer with professional
service and high quality products.
Q: How does your factory do as quality control?
A: We strictly in accordance with inspection standard of zero-defect products, and constantly improve the strict quality
management system. QC will inspect every component every three hours, while the front-line production staff also inspect every two hours.
APP
Post My RFQ
WhatsApp
+86-17326049340