Model Number:
-
PCM-L13S50-D02
-
Specified Types:
-
13S Li-ion/Li-polymer/LiFePO4 Battery Pack
-
Li-ion/Li-polymer Charging Voltage:
-
48.1V
-
LiFePO4 Charging Voltage:
-
46.8V
-
Max. continuous charging current:
-
50a(Max)
-
Maximal continuous discharging current:
-
50a(Max)
-
Discharge overcurrent protection:
-
120±30A(adjustable)
-
Colour of PCM:
-
Green
-
Warranty:
-
12 months
-
Dimension:
-
L95*W91.3*T8mm
-
Balance:
-
YES
Quick Details
-
Application:
-
Electric Folklifts
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
quawin/OEM
-
Model Number:
-
PCM-L13S50-D02
-
Specified Types:
-
13S Li-ion/Li-polymer/LiFePO4 Battery Pack
-
Li-ion/Li-polymer Charging Voltage:
-
48.1V
-
LiFePO4 Charging Voltage:
-
46.8V
-
Max. continuous charging current:
-
50a(Max)
-
Maximal continuous discharging current:
-
50a(Max)
-
Discharge overcurrent protection:
-
120±30A(adjustable)
-
Colour of PCM:
-
Green
-
Warranty:
-
12 months
-
Dimension:
-
L95*W91.3*T8mm
-
Balance:
-
YES
Technical parameter
Product name:Protection Circuit Module
Model No:PCM-L13S50-D02
For 6-13S Lithium-ion/Lithium Polymer/LiFePO4 Battery Packs
Product Feature:
1. It can control low-temperature heating. When the working current is set, start heating the heating device at -20 to -5ºC, and stop heating when the temperature is higher than 0ºC.
2. Temperature switch controls the temperature of discharge detection battery;
3. The maximum continuous working current is 50A, and the charging/discharging interface is the same;
4. Weak current switch controls discharge output;
5. Suitable for 6~13 section Lithium-ion/Lithium Polymer/LiFePO4 Battery Packs;
Items | Specifications | ||
Lithium-ion/Lithium Polymer | LiFePO4 | ||
Charge | Charging voltage(CC/CV)-13S | CC/CV:54.6V | CC/CV:46.8V |
Maximal continuous charging current | 50A | ||
Discharge | Maximal continuous discharging current | 50A | |
Low current consumption | Current consumption on operation | <20μA | |
Current consumption at power down | <0.1μA | ||
Cell-balance | Cell-balance detection voltage | 4.20 ± 0.03 V | 3.60 ± 0.03 V |
Cell-balance release voltage | 4.20 ± 0.03 V | 3.60 ± 0.03 V | |
Cell-balance current | 68 ±3mA | 58 ±3mA | |
Over-charge | Overcharge detection voltage | 4.25±0.025V | 3.900 ± 0.025V |
Overcharge release voltage | 4.15±0.05V | 3.800 ± 0.050V | |
Overcharge delay time | 0.5~2S | ||
Over-discharge | Overdischarge detection voltage | 2.50±0.062V | 2.00±0.080V |
Overdischarge release voltage | 3.0±0.075V | 2.30±0.100V | |
Overdischarge delay time | 100~250mS | ||
Discharge overcurrent | Discharge overcurrent detection voltage | 0.2±0.015V | 0.10±0.015V |
Discharge overcurrent delay time | 15~35ms | ||
Discharge overcurrent protection | 120±30A(can adjust) | ||
Release condition | Cut-off-load | ||
Short-circuiting protection | Load short-circuiting detection voltage | / | / |
Detection condition | Exterior short circuit | ||
Load short-circuiting detection delay time | 200~800μs | ||
Release condition | Cut-off-load | ||
Internal resistance | Static Drain-Source On-Resistance | <40mΩ(B- to P-) | |
Temperature | Wide range of operation temperature | 40 ~ + 85ºC | |
Storage Temperature Range | -40 ~ +125ºC | ||
Dimension | L95*W91.3*T8mm |