- Product Details
- {{item.text}}
Quick Details
-
Place of Origin:
-
Jiangsu, China
-
Product name:
-
Nucleic Acid Extractor
-
Certification:
-
CE/RoHS
-
One-time Sample Extraction Number:
-
32
-
Processing Volume:
-
50uL-1000uL
-
Sample Volume:
-
20uL-500uL
-
Magnetic Bead Recovery:
-
>99%
-
Easy Operation:
-
No Pretreatment
-
Pollution Prevention Design:
-
With 12-level HEPA Filter
-
High Fitness:
-
Be Used With More than 100 Kinds Of Special Reagent Kits
-
Function:
-
Extract Nucleic Acid
Quick Details
-
Warranty:
-
3 years
-
After-sale Service:
-
Online technical support
-
Brand Name:
-
Bioteke
-
Place of Origin:
-
Jiangsu, China
-
Product name:
-
Nucleic Acid Extractor
-
Certification:
-
CE/RoHS
-
One-time Sample Extraction Number:
-
32
-
Processing Volume:
-
50uL-1000uL
-
Sample Volume:
-
20uL-500uL
-
Magnetic Bead Recovery:
-
>99%
-
Easy Operation:
-
No Pretreatment
-
Pollution Prevention Design:
-
With 12-level HEPA Filter
-
High Fitness:
-
Be Used With More than 100 Kinds Of Special Reagent Kits
-
Function:
-
Extract Nucleic Acid
Products Description
BioTeke's Automated Nucleic Acid Extraction System uses cutting-edge magnetic bead separation technology to achieve fast and easy operation of DNA/RNA automation extraction procedure.
All separation and purification procedures are completed in 96 well plates and there is no need for steps like regular centrifugation and filtering required by extraction and purification.
The system can complete fast extraction and purification process from samples,
including but not limited to blood, tissue, cells, swab, virus and other clinical or forensic samples.
The extracted high quality DNA/RNA is ready for use in highly sensitive downstream analysis, such as qPCR, clinical molecular diagnostic, analysis of gene expression, gene analysis, forensic and infectious disease research etc.
The purified nucleic acid can be applied directly for the next enzyme cleavage, identification as well as disease diagnosis and treatment etc. As a famous domestic nucleic acid separation and purification technology company, BioTeke provides over 100 kinds of extraction kits for use with this instrument to maximize its application and minimize its costs.
![](https://cdn.bestsuppliers.com/seo_products_img/bioteketwo/6b0de7900e433f83a828ab67fef3e3eb.jpg!/rotate/180)
Model
|
|
AU1001S
|
|
|
|||
Sample Quantity
|
|
32
|
|
|
|||
Processing Volume
|
|
50µL-1000µL
|
|
|
|||
Sample Volume
|
|
20µL-500µL
|
|
|
|||
Sample Throughput
|
|
1-32
|
|
|
|||
Magnetic Bead Recovery
|
|
>99%
|
|
|
|||
Extracting the Difference Between Holes
|
|
CV≤3%
|
|
|
|||
Heating Temperature
|
|
4 independent heating modules
|
|
|
|||
UV germicidal lamp
|
|
YES
|
|
|
|||
Reagent Type
|
|
Magnetic bead open platform
|
|
|
|||
Extraction Time
|
|
9.5min/round (depending on the reagent used)
|
|
|
|||
Internal Program
|
|
Be able to store >100 groups of programs
|
|
|
|||
Program Management
|
|
Powerful program editing capabilities to meet different reagent needs. U disk program import and export can be achieved
|
|
|
|||
Packing Size(W*D*H)mm
|
|
480*490*640(L*W*H)
|
|
|
|||
Gross Weight(kg)
|
|
20KG
|
|
|
![](https://cdn.bestsuppliers.com/seo_products_img/bioteketwo/cc10f3c60aa137d3b91705c236d1fd97.jpg!/rotate/180)
Model
|
|
AU1001-96
|
|
|
|||
Sample Quantity
|
|
96
|
|
|
|||
Processing Volume
|
|
50µL-1000µL
|
|
|
|||
Sample Volume
|
|
20µL-500µL
|
|
|
|||
Sample Throughput
|
|
1-96
|
|
|
|||
Magnetic Bead Recovery
|
|
>99%
|
|
|
|||
Extracting the Difference Between Holes
|
|
CV≤3%
|
|
|
|||
Heating Temperature
|
|
2 independent heating modules
|
|
|
|||
Reagent Type
|
|
Magnetic bead open platform
|
|
|
|||
Extraction Time
|
|
9.5min/round (depending on the reagent used)
|
|
|
|||
Internal Program
|
|
Be able to store >100 groups of programs
|
|
|
|||
Program Management
|
|
Powerful program editing capabilities to meet different reagent needs. U disk program import and export can be achieved
|
|
|
|||
Packing Size(W*D*H)mm
|
|
970*690*850(L*W*H)
|
|
|
|||
Gross Weight(kg)
|
|
101KG
|
|
|
![](https://cdn.bestsuppliers.com/seo_products_img/bioteketwo/bf73c5e0dffc397f8d67f5595279e391.jpg!/rotate/180)
Operation Process
1.Add Samples
2.Tear off the preseal-ing film and put it to the corresponding plate position
3.Edit the program, and select the program
4.Click on the program to start running
5.Extrsaction was completed,and the purified nucleic acid was obtained
6.End of operation,do UV disinfection
Products Advantages
1. Large screen English operation panel:
Large screen, full color display, touch screen English operation panel, easy to use.
2. Precise control
Built-in engineering computer, no need to connect to PC. Single machine operation can help save more space and energy and provide highly stable automatic control system.
4. Free programming
Powerful program editing function allows flexible and efficient defining of your application to meet requirements of various reagents.
5. High purity & high yield
The purification program can be optimized based on reagents. And with precise incubation time, higher extraction efficiency can be achieved. The highly purified DNA/RNA can be used directly for PCR and RT-PCR.
Large screen, full color display, touch screen English operation panel, easy to use.
2. Precise control
Built-in engineering computer, no need to connect to PC. Single machine operation can help save more space and energy and provide highly stable automatic control system.
3. Temperature control
Customer can define lysis and elution temperature as needed.
Customer can define lysis and elution temperature as needed.
4. Free programming
Powerful program editing function allows flexible and efficient defining of your application to meet requirements of various reagents.
5. High purity & high yield
The purification program can be optimized based on reagents. And with precise incubation time, higher extraction efficiency can be achieved. The highly purified DNA/RNA can be used directly for PCR and RT-PCR.
6
. Stable results
Discrepancies and errors caused by manual operation can be avoided. The results are stable and come with good repeatability.
Discrepancies and errors caused by manual operation can be avoided. The results are stable and come with good repeatability.
![](https://cdn.bestsuppliers.com/seo_products_img/bioteketwo/57c70c8b690a334ab8adc1fa889090cb.jpg!/rotate/180)