Prefab metal light steel structure frame prefabricated high rise apartment steel structure building
- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
SYLY
-
Model Number:
-
Q355B Q235B
-
Certificate:
-
ISO9001:2008/CE/BV/CWB
-
color:
-
Blue Red White Green Etc
-
Body frame:
-
Q355B/Q235B welded steel
-
Beam:
-
Welded/ Hot rolled H beam
-
Purlin:
-
C.Z Shape Steel Channel
-
Ext wall:
-
EPS sandwich panel
-
Door and window:
-
PVC or Aluminum alloy/ Sliding door or rolled door
-
Surface treatment:
-
Hot Dip Galvanised or painted
-
Drawing Design:
-
AutoCAD /PKPM /MTS/3D3S/TARCH
-
Earthquake Resistance:
-
Grade 7
Quick Details
-
Grade:
-
Q235 Q355
-
Tolerance:
-
±1%
-
Place of Origin:
-
Liaoning, China
-
Brand Name:
-
SYLY
-
Model Number:
-
Q355B Q235B
-
Certificate:
-
ISO9001:2008/CE/BV/CWB
-
color:
-
Blue Red White Green Etc
-
Body frame:
-
Q355B/Q235B welded steel
-
Beam:
-
Welded/ Hot rolled H beam
-
Purlin:
-
C.Z Shape Steel Channel
-
Ext wall:
-
EPS sandwich panel
-
Door and window:
-
PVC or Aluminum alloy/ Sliding door or rolled door
-
Surface treatment:
-
Hot Dip Galvanised or painted
-
Drawing Design:
-
AutoCAD /PKPM /MTS/3D3S/TARCH
-
Earthquake Resistance:
-
Grade 7
Contact us
Product Display
Items
|
Specifications
|
|
Main structure
|
PEB Welded H-shaped steel or hot rolled steel, Q355 or Q235
|
|
Anti-rust protection
|
Hot dip galvanized or anti-rust painting
|
|
Pu
rlins and girts
|
Cold rolled C or Z steel, Q355 or Q235
|
|
Roof and wall
|
Single layer steel sheet or sandwich panel
|
|
Gutter
|
Heavy duty galvanized steel
|
|
Down pipe
|
PVC
|
|
Door
|
Sliding door or roller shutter
|
|
Windows
|
PVC or aluminum alloy
|
|
Other components available upon request. Please provide the following information for detailed custom design.
|
|
Basic Building Parameters We Take into Consideration
Building Width:
No matter what primary framing system is used, the building width is defined as the distance from outside of eave strut of one
sidewall. Building width does not include the width of Lean-To buildings or roof extensions.
Building Length:
The longitudinal length of the building measured from out to out of end wall steel lines
Building Height:
Building height is the eave height which usually is the distance from the bottom of the main frame column base plate to the top outer point of the eave strut. When columns are recessed or elevated from finished floor, eave height is the distance from finished floor level to top of eave strut.
Roof Slope (x/10):
This is the angle of the roof with respect to the horizontal .The most common roof slopes are 0.5/10 and 1/10. Any practical roof slope is possible.
End Bay Length:
The distance from outside of the outer flange of end wall columns to center line of the first interior frame column.
Interior Bay Length:
The distance between the center lines of two adjacent interior main frame columns.The most common bay lengths are 6m,7.5m and 9m.
Design loads:
Design for snow loads,earth quake loads,collateral loads.crane loads or any other loading condition,if required must be specified at the time of request for quotation.
No matter what primary framing system is used, the building width is defined as the distance from outside of eave strut of one
sidewall. Building width does not include the width of Lean-To buildings or roof extensions.
Building Length:
The longitudinal length of the building measured from out to out of end wall steel lines
Building Height:
Building height is the eave height which usually is the distance from the bottom of the main frame column base plate to the top outer point of the eave strut. When columns are recessed or elevated from finished floor, eave height is the distance from finished floor level to top of eave strut.
Roof Slope (x/10):
This is the angle of the roof with respect to the horizontal .The most common roof slopes are 0.5/10 and 1/10. Any practical roof slope is possible.
End Bay Length:
The distance from outside of the outer flange of end wall columns to center line of the first interior frame column.
Interior Bay Length:
The distance between the center lines of two adjacent interior main frame columns.The most common bay lengths are 6m,7.5m and 9m.
Design loads:
Design for snow loads,earth quake loads,collateral loads.crane loads or any other loading condition,if required must be specified at the time of request for quotation.
Basic design requirements and design Load,
1. Project site location ;
2. Overall dimension (length*width*eave height in meters);
3. Mezzanine or not? How many kgs of load per square meter on mezzanine?;4. Single-layer steel sheet wall or sandwich panel wall;
5. Snow load if applicable;
6. Wind speed/load;
7. Interior column allowed or not;
8. Overhead crane needed or not, capacity?;
9. Any other particular requirements?
Building Purpose: we will recommend the best design for the purpose of the building.
A. Warehouse/Storage
B. Factory
C. Agriculture Barn
D. Retail Store
E. Repair/Mechanic Shop
F. Office Space
G. Medical Warehouse
H. Animal Farm (please confirm what kind of animal)
Design Strength+Certifications
Widely used prefabricated steel structure gas station petrol station design storage buildings warehouse
Hot Searches