Products
SWQ1 63amp automatic transfer switch ATS switch controller 2p Change Over Switch Overload and Short Circuit
SWQ1 63amp automatic transfer switch ATS switch controller 2p Change Over Switch Overload and Short Circuit
SWQ1 63amp automatic transfer switch ATS switch controller 2p Change Over Switch Overload and Short Circuit
SWQ1 63amp automatic transfer switch ATS switch controller 2p Change Over Switch Overload and Short Circuit
SWQ1 63amp automatic transfer switch ATS switch controller 2p Change Over Switch Overload and Short Circuit
SWQ1 63amp automatic transfer switch ATS switch controller 2p Change Over Switch Overload and Short Circuit

SWQ1 63amp automatic transfer switch ATS switch controller 2p Change Over Switch Overload and Short Circuit

FOB Reference Price: Get Latest Price
≥500 Pieces
US $1
Free Inquiry
Customized Request
  • Product Details
  • {{item.text}}

Quick Details

Brand Name:
singi
Model Number:
swq1-63
Rated Current:
63A
rated voltage:
220/380VAC
rated current:
6,10,16,20,25,32,40,50,63amp
pole:
4
case material:
PA66
standard:
IEC60898
breaking capacity:
6KA
protection:
overload and short circuit
OEM:
avaiable
Keywords:
automatic transfer switch
keywords2:
ats

Quick Details

Type:
CB
Number of Pole:
4
Place of Origin:
Zhejiang, China
Brand Name:
singi
Model Number:
swq1-63
Rated Current:
63A
rated voltage:
220/380VAC
rated current:
6,10,16,20,25,32,40,50,63amp
pole:
4
case material:
PA66
standard:
IEC60898
breaking capacity:
6KA
protection:
overload and short circuit
OEM:
avaiable
Keywords:
automatic transfer switch
keywords2:
ats

Key Specification

SWQ1  63amp  automatic or manual 2pole change over switch

original metal components suppler of CHNT&Delixi

Why choose us

  • Professionally specialized in low voltage construction electrical product
  • Chinese famous trademark;
  • Original factory established in 1993;
  • We have our own mold and punching plants, the price ,quality, aftersale and customization etc. can be well controlled;
  • Stable parts supplier of ,ABB,CHNT, Delixi, Gacia etc. famous, national enterprises;
  • Production strictly according to ISO9001;
  • CE,CB,UL,CUL,ETL,CETL certified;
  • Annual sales amount 90million USD;
  • Wide product range: mcb, mccb, ats, auto-reclosing, distribution box ,switch and socket, power strip,

metal stampings, terminal box, communication wire;

  • OEM and ODM are welcomed;
  • Good and honest service;
  • Our products are used in Shanghai World Expo in 2009;
  • Timely delivery and good aftersale;

Introduction

GNQ1series miniature circuit breaker automatic transfer switch is composed of two mcb and its auxiliary parts. It is suitable to the double power system of AC power below 415V,frequency 50/60Hz,rated current below63A. The main applied places include hospital, shopping mall, bank, fire control ,telecommunication, high-rising building etc. where the power off is not allowed.

Features

l With small volume, simple structure ,easy operation ,long life ,3/4pole available;

l The switching drive is single motor ,stable ,without noise, impact small;

l With mechanical and electric interlock, switching reliable ,manual and automatic transfer optional;

l The rated current of normal power mcb and backup power mcb can be different;

l The terminal in ATS is for user wiring to display the close or open station of mcb;

l The mcb has high breaking capacity.

Working Condition

l The around air temperature should be between +5 °C and +40 °C ,the average value should be not higher than 35 °C ;

l The sea level should not exceed 2,000m;

l The air relative humidity should not exceed 50%,lower temperature ,the humidity can be higher, the average temperature +25 °C ,,the max relative humidity should not exceed 90% and the surface condensation should be taken into consideration cause of the temperature change;

l Pollution degree III;

l The working place is without strong vibration and impact, no corrosive gas that corrode metal and break the insulation, no strong dust, no conductive particulate and explosive dangerous substance, no strong electromagnetic interference.

Parameter

Pole

Rated voltage Ue(VAC)

Rated current In(AAC)

Rated frequency

(Hz)

Control Voltage

(V)

Transfer time(s)

Limit breaking capacity(A)cos

Mechanical life(times)

2

220

6,10,16,20,

25,32,40,

50,63

50/60

220

1.5-3

6,000/0.65

10,000

3

380

4,500/0.7

4

Wiring

Remark: chose the suitable wire ,connect the wire-in and wire-out of mcb well and the phase sequence of wire-in should be accordant. For 3 pole mcb, add neutral line of each mcb to the neutral N terminal of ATS, or the ATS can not work normally.




Company Introduction

Who We Are

SINGI established in1980, with annual sales amount more than 90 million USD,
presently we have three production bases located in Liushi town, Yueqing in Wenzhou and Shanghai.

  • In Liushi, mainly terminal block is manufactured ;
  • In Yueqing, mainly low voltage construction electrical products are manufactured, like MCCB,MCB, Air Circuit Breaker, Switch &Socket, Distribution Box, ATS, Auto-reclosing etc. and the components which needed by above products;
  • In Shanghai, mainly Household Telecom Cable Wire are produced.

All production and management are carried strictly according to ISO9001 and products have been certified CE,CB,UL,CUL,ETL,CETL.

ralated keywords:

mcb circuit breaker/ 10amp circuit breaker/ mcb/ miniature circuit breaker / mini circuit breaker / miniature circuit breaker mcb/ circuit breaker mcb / circuit breaker/ miniature circuit breakers/ mini circuit breakers/ circuit breaker 100amp/ resident miniature circuit breaker/ circuit breaker 16a/ residual mini circuit breaker/ circuit breakers/ 240V circuit breaker/ 1amp circuit breaker/ DIN rail circuit breaker/ 40amp circuit breaker/ double pole circuit breaker/ 25amp circuit breaker/ circuit breaker switch

APP
Post My RFQ
WhatsApp
+86-17326049340