- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
HZDQ insulating gloves test
-
Model Number:
-
HZ-11 insulating gloves test
-
Name:
-
insulating gloves test
-
Rated output voltage:
-
50kV
-
Rated Capacity:
-
5kVA
-
The output voltage range:
-
50.0kV(250V)
-
Voltage measurement error:
-
<0.2%U±0.02%
-
Input Current Range:
-
25.0A
-
Current measurement error:
-
<0.2%/ ± 0.02%
-
Leakage current range:
-
25.0mA
-
Leakage current measurement error:
-
<0.5%/2 ± words
-
Leakage current resolution:
-
0.1mA
Quick Details
-
Warranty:
-
1 YEAR
-
Power:
-
Electronic
-
Place of Origin:
-
Hebei, China
-
Brand Name:
-
HZDQ insulating gloves test
-
Model Number:
-
HZ-11 insulating gloves test
-
Name:
-
insulating gloves test
-
Rated output voltage:
-
50kV
-
Rated Capacity:
-
5kVA
-
The output voltage range:
-
50.0kV(250V)
-
Voltage measurement error:
-
<0.2%U±0.02%
-
Input Current Range:
-
25.0A
-
Current measurement error:
-
<0.2%/ ± 0.02%
-
Leakage current range:
-
25.0mA
-
Leakage current measurement error:
-
<0.5%/2 ± words
-
Leakage current resolution:
-
0.1mA
Huazheng Electric hipot tester 50kv automated Insulating materials gloves test bench insulation boots leakage current test set
gloves testing
Insulated boots and gloves are essential power system operation and maintenance of safety equipment, DL408 electricity safety regulations and electrical insulation shoes GB12011-2000 General technical requirements and test methods specified period insulated boots and gloves and other safety equipment used in . Test methods and cycles insulated boots and gloves and other safety equipment used for. Insulated boots and gloves pressure test, a period of six months, the breakdown is not allowed during the test, and insulated boots leakage current is less than the limit value.
gloves testing Features:
1. Simultaneously 8 insulated boots or gloves trials were measured leakage current
2. Display large amount of information
3. Measurable test voltage test transformer primary current and other parameters
4. Using infrared communications technology
5. Automatic pressure test
6. With a dedicated ground containers, easy to operate
7. With over-voltage, overcurrent and other functions
gloves testing Parameters:
![]() |
1. Rated output voltage: 50kV 2. Rated Capacity: 5kVA 3. The output voltage range:50.0kV(250V) 4. Voltage measurement error: <0.2%U±0.02% 5. Input Current Range : 25.0A 6. Current measurement error :<0.2%/ ± 0.02% 7. Leakage current range :25.0mA 8.Leakage current measurement error :<0.5%/2 ± words 9. Leakage current resolution :0.1mA 10. Digital timer :10~990S 11. Host size :430×310×370 12. Weight:28kg |

From the date of purchase within one year instrument, is a product quality problem free repair replacement, lifetime supply of maintenance and technical services. The instrument has found anomalies or malfunctions please contact us to arrange the most convenient treatment options.