Products
Endress Hauser/ Radar water tank level sensor/water level meter gauge FMR50
Endress Hauser/ Radar water tank level sensor/water level meter gauge FMR50
Endress Hauser/ Radar water tank level sensor/water level meter gauge FMR50
Endress Hauser/ Radar water tank level sensor/water level meter gauge FMR50
Endress Hauser/ Radar water tank level sensor/water level meter gauge FMR50
Endress Hauser/ Radar water tank level sensor/water level meter gauge FMR50
Endress Hauser/ Radar water tank level sensor/water level meter gauge FMR50
Endress Hauser/ Radar water tank level sensor/water level meter gauge FMR50

Endress Hauser/ Radar water tank level sensor/water level meter gauge FMR50

FOB Reference Price: Get Latest Price
≥5 Pieces
US $1000
Free Inquiry
Customized Request
  • Product Details
  • {{item.text}}

Quick Details

Brand Name:
Endress Hauser
Model Number:
Radar measurement FMR50
Application:
For basic level measurement in liquids, pastes and slurries
Frequency:
K-band (~26 GHz)
Accuracy:
+/- 2 mm (0.08 in)
Material:
VDF, PTFE, Viton, PP, PBT
Process temperature:
-40...+130 °C (-40...+266 °F)
max. overpressure limit:
Vacuum...3 bar (Vacuum...43.5 psi)
Supply / Communication:
2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus) 4-wire (HART)
Process Connect:
Thread: G1 1/2, MNPT1 1/2 Flange: UNI DN80...DN150 (3"...6")
Measuring range:
Standard: 30 m (98 ft) With enhanced dynamics: 40 m (131 ft)

Quick Details

Grade:
Industrial
Warranty:
1 year
Place of Origin:
Germany
Brand Name:
Endress Hauser
Model Number:
Radar measurement FMR50
Application:
For basic level measurement in liquids, pastes and slurries
Frequency:
K-band (~26 GHz)
Accuracy:
+/- 2 mm (0.08 in)
Material:
VDF, PTFE, Viton, PP, PBT
Process temperature:
-40...+130 °C (-40...+266 °F)
max. overpressure limit:
Vacuum...3 bar (Vacuum...43.5 psi)
Supply / Communication:
2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus) 4-wire (HART)
Process Connect:
Thread: G1 1/2, MNPT1 1/2 Flange: UNI DN80...DN150 (3"...6")
Measuring range:
Standard: 30 m (98 ft) With enhanced dynamics: 40 m (131 ft)

Radar measurement Time-of-Flight Micropilot FMR50

Basic model for level liquid applications


Micropilot FMR50 is the best choice in simple reservoir and storage applications as well as in utility processes. The FMR50 free space radar is used for continuous, non-contact level measurement of liquids, pastes and slurries. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.

Benefits

  • Reliable non-contact measurement even for changing product and process conditions

  • HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics

  • Highest reliability even in the presence of obstructions in the vessel due to new Multi-Echo Tracking evaluation

  • Hardware and software developed according to IEC 61508 up to SIL3 (in homogeneous redundancy)

  • Seamless integration into control or asset management systems

  • Intuitive, menu-guided operation concept (on-site or via the control system)

  • World's easiest proof test concept for SIL and WHG saves time and cost

Field of application

Encapsulated PVDF or PP-plated horn antenna.

  • Process connections: Thread, mounting bracket or slip-on flange

  • Temperature: -40 to +130°C (-40 to +266°F)

  • Pressure: -1 to +3bar (-14.5 to +43.5psi)

  • Maximum measuring range: 30m (98ft), 40m (131ft) for enhanced dynamics

  • Accuracy: ±2mm

  • K-band: 26GHz

  • International explosion protection certificates, overfill prevention WHG, SIL, 5-point linearity protocol

Features and specifications

Measuring Principle Level radar
Characteristic / Application For basic level measurement in liquids, pastes and slurries; non affected by changing media, temperature changes, gas blankets or vapor;
Encapsulated PVDF or PP clad horn antenna
Supply / Communication 2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
4-wire (HART)
Frequency K-band (~26 GHz)
Accuracy +/- 2 mm (0.08 in)
Ambient temperature -40...+80 °C
(-40...+176 °F)
Process temperature -40...+130 °C
(-40...+266 °F)
Process pressure absolute / max. overpressure limit Vacuum...3 bar
(Vacuum...43.5 psi)
Main wetted parts PVDF, PTFE, Viton, PP, PBT
Process connection Thread:
G1 1/2, MNPT1 1/2
Flange:
UNI DN80...DN150 (3"...6")
Max. measurement distance Standard: 30 m (98 ft)
With enhanced dynamics: 40 m (131 ft)
Output 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, NEPSI, INMETRO, KC
Overfill prevention WHG
SIL
Options Display
Customized parameterization
PWIS free
Specialities SIL 2 according to IEC 61508,
Safety and reliability with Multi-Echo Tracking,
HistoROM
Application limits Maximum measuring range is dependent on the tank form and/or application:

Ammoniacal gas phase:
FMR54 in stilling well
Strong buildup formation:
FMR54 with air purge
Low DK:
FMR51
Only PTFE resistant:
FMR52
Custody transfer measurement:
FMR5xx

Product pictures:

Packaging & Shipping

Single carton package

Package for special products(following is radiative resource)

Transfer with tray

Shipping with wooden case

Shipment
  • We ship by DHL,UPS,Fedex,TNT,EMS express,Air Ship,Sea ship and so on at the reasonable time.
  • DHL,UPS,Fedex,TNT usually takes about 4~6 days,EMS usually takes about 4~13days,more or less,if the deliver region is remote, it will be a little longer, if due to buyer's custom reason, it depends on your customs.
APP
Post My RFQ
WhatsApp
+86-17326049340