Products
Water reverse osmosis 1 ton 500liter per hour deionized water machine central softener desalination water filter
Water reverse osmosis 1 ton 500liter per hour deionized water machine central softener desalination water filter
Water reverse osmosis 1 ton 500liter per hour deionized water machine central softener desalination water filter
Water reverse osmosis 1 ton 500liter per hour deionized water machine central softener desalination water filter
Water reverse osmosis 1 ton 500liter per hour deionized water machine central softener desalination water filter
Water reverse osmosis 1 ton 500liter per hour deionized water machine central softener desalination water filter
Water reverse osmosis 1 ton 500liter per hour deionized water machine central softener desalination water filter
Water reverse osmosis 1 ton 500liter per hour deionized water machine central softener desalination water filter

Water reverse osmosis 1 ton 500liter per hour deionized water machine central softener desalination water filter

FOB Reference Price: Get Latest Price
≥1 Sets
US $1850
≥5 Sets
US $1750
Free Inquiry
Customized Request
  • Product Details
  • {{item.text}}

Quick Details

Weight (KG):
100 kg
Product name:
UF water system
Function:
Water Purification
Application:
Hotels, Garment Shops, Building Material Shops, Manufacturing Plant
Model:
CK-8T UF + 6T RO
Certification:
CE ISO
Environment Temperature:
5~45°C
Voltage:
220V

Quick Details

Place of Origin:
Guangdong, China
Brand Name:
chunke
Material:
wooden, FRP, PE, UPVC
Weight (KG):
100 kg
Product name:
UF water system
Function:
Water Purification
Application:
Hotels, Garment Shops, Building Material Shops, Manufacturing Plant
Model:
CK-8T UF + 6T RO
Certification:
CE ISO
Environment Temperature:
5~45°C
Voltage:
220V

Deionized water machinee

What is Reverse Osmosis?

Reverse osmosis (R/O) is a water treatment process in which water is forced through a semi-permeable membrane that has very small holes or "pores". Clean water passes through and impurities that are too big to pass through the membrane are left behind and flushed away. In a word, it is a machine to make pure/ultra pure water.

Function of each part of water treatment plant

1. Feed water pump pump-- provide the pressure to quartz sand filter/active carbon filter

2. Multi-medium filter-- get rid of turbidity, suspended matter, organic matter, colloid, ect.

3. Active Carbon filter--Remove the color, free chloride, organic matter, harmful matter, ect.

4. Softener--exchange "ions" of calcium and magnesium with the most common and easiest method.

5. Security filter--prevent large particles, bacteria, viruses into RO membrane, accuracy is 5u

6. High pressure pump-- Provide the high pressure to RO membrane

7. RO system-- main part of the plant. The RO membrane's desalting rate can reach 99%, removing over 99% ions

8. UV sterilizer or ozone generator--- kill bacteria

Technical Parameter

Model

Productivity (T/H)

Motor Power(KW)

Recovery Rate(%)

Pure Water Conductivity (us/cm)

Raw Water Conductivity (us/cm)

CK-RO-500L

0.5

1.5

50

10

≤300

CK-RO-1000L

1

2.2

50

10

≤300

CK-RO-2000L

2

3

50-60

10

≤300

CK-RO-3000L

3

4.5

55-65

10

≤300

CK-RO-4000L

4

6.5

55-65

10

≤300

CK-RO-5000L

5

8

60-70

10

≤300

CK-RO-10T

10

18

65-75

10

≤300

CK-RO-20T

20

30

70-75

10

≤300

CK-RO-30T

30

40

70-75

10

≤300

CK-RO-50T

50

70

70-75

10

≤300

CK-RO-100T

100

115

70-75

10

≤300

CK-RO-200T

200

230

70-75

10

≤300

How Do I Know Which Size Unit to Buy?

General guidelines for modeling an RO system to take into consideration are the silt density index (SDI) measurement of the feed water after pretreatment. Derived from experience, limits on permeate flux and element recovery for different types of waters are based on correlation of the SDI value with membrane fouling and mineral content with element recovery, respectfully, for different types of waters. These general limits shown in Table 1 below serve as boundary conditions when designing a RO system. A system designed with high permeate flux rates for example is likely to experience  higher fouling rates and more frequent chemical cleanings.  Due to high salinity (>36,000 ppm TDS), seawater system designs are further limited by the osmotic pressure and durability of the membrane elements.

What should i prepare when i need a quote ?

Raw water condition: Water Quality Analysis Report / TDS

Raw water source: Tap water, groundwater, seawater, or river water etc.

What does water use for: Drinking water, domestic water, breeding, irrigation, printing and dyeing,  , cosmetics, etc.

Quantity: How many do you need for water treatment machine.

Before and after service?

1. We can provide overseas services to help customers install on site.

2. We are pure manufacturer. When there is a problem with your water treatment equipment or about water quality, we are willing to provide solutions and equipment.

3. The technical engineer has the certificate of Senior water treatment Engineer.

4. More than 10 years of professional welding engineer and domestic water treatment design engineer.

5. We have passed ISO9001 quality management system certification and SGS certification.

6. Water treatment equipment testing, early and late delivery have synchronized information.

7. We have our own brand "CHUNKE ”.

APP
Post My RFQ
WhatsApp
+86-17326049340