Products
Vacuum Air Flow Diaphragm Adjusting Indicator Hvac Adjustable Pressure Differential Switch
Vacuum Air Flow Diaphragm Adjusting Indicator Hvac Adjustable Pressure Differential Switch
Vacuum Air Flow Diaphragm Adjusting Indicator Hvac Adjustable Pressure Differential Switch
Vacuum Air Flow Diaphragm Adjusting Indicator Hvac Adjustable Pressure Differential Switch
Vacuum Air Flow Diaphragm Adjusting Indicator Hvac Adjustable Pressure Differential Switch
Vacuum Air Flow Diaphragm Adjusting Indicator Hvac Adjustable Pressure Differential Switch
Vacuum Air Flow Diaphragm Adjusting Indicator Hvac Adjustable Pressure Differential Switch
Vacuum Air Flow Diaphragm Adjusting Indicator Hvac Adjustable Pressure Differential Switch

Vacuum Air Flow Diaphragm Adjusting Indicator Hvac Adjustable Pressure Differential Switch

FOB Reference Price: Get Latest Price
≥10 Pieces
US $7.8
≥100 Pieces
US $7.25
Free Inquiry
Customized Request
  • Product Details
  • {{item.text}}

Quick Details

Model Number:
ILH351-Series
Max. Current:
1.5A (0.4A)
Max. Working Pressure:
10Kpa
Pressure Medium:
Air,non-combustible and non-aggressive gas
Working Temp:
-20~85°C
Protection level:
IP54
Connections:
Dia 6.4mm for the tube connection
Storage temp:
-40~85°C
Rated voltage:
220V/240V 110V-120V

Quick Details

Max. Voltage:
250V AC
Place of Origin:
Beijing, China
Brand Name:
OEM avaliable
Model Number:
ILH351-Series
Max. Current:
1.5A (0.4A)
Max. Working Pressure:
10Kpa
Pressure Medium:
Air,non-combustible and non-aggressive gas
Working Temp:
-20~85°C
Protection level:
IP54
Connections:
Dia 6.4mm for the tube connection
Storage temp:
-40~85°C
Rated voltage:
220V/240V 110V-120V
Products Description
Differential Pressure Switch ILH351
1 . General Information The information provided in this instruction sheet should be sufficient for installation and adjustment of the ILH351. For additional infommation you could obtain the ILH351 product data sheet. Series of l LH351 differential pressure switch has been designed for interlock purposes or no differential pressure detection . Where critical or high value property is to be maintained within specific environmental conditions , a single control should not be applied to function as both an operating and safety device . In such applications , a separate back-up control with alarm contacts should be wired to indicate when this control operates . Series of LH351 pressure switch can be used to sense( Differential ) pressure and flow of air in ducts and pipes. Typical applications include: -Filter obstructive alarm . - Air provingin ventilation ducts. - Maximum airflow controller for variable air volum systems. -Burner air control.
2 . Technical Specifications Measuring Range: ILH351-A : 20pa-300pa ILH351-B : 50pa-500pa ILH351-C : 200pa-1000pa ILH351-D : 500pa-2500pa Max. Medium Pressure : 2500pa Working Temperature: 15°C- + 60°C ( Over-pressure 2500pa) Protection levels : IP54. Out put contact capacity : 250V 2A , Contact shift. Weight : 100g Dimension: φ 81 x 53mm
3 . Pressure Connection and Wiring Pressure connections are marked with Incorrect connections are forbidden
4 . Installation Location : select a location where vibrations are minimal.Ambient temperature should be within the range of-15 / + 60°C . The production calibration of the ILH351 is made at room temperature; mounting locations close to room temperatures are preferred In systems with high humidity where condensations possible , thus the entrance should point downwards.
5 . Mounting Instruction The switch is preferably mounted with the diaphragm in a vertical plane , unless the device is set or calibrated for horizontal mounting as on special customer models . On these models the mounting position is indicated on the side of the control . It may be fastened directly tothe duct heater or panel as long as the mounting surface has minimal or no vibrationin. Pressure Connections are marked +( high pressure ) and-low or static pressure ) . For more information ,please read the diagram on the side of the control.
6 . Notice To drill a hole through the plastic tube or pipe before installation , and also mount part of L-bracket on the spot ( Standard setting ). 7 . Accessory Consists ( φ6.2mm 1.8m ) plastic tubes , 1L-bracket 3screws, 2 pressure-adapted tubes *The Pressure Switch should be mounted vertically which can prevent affecting on precision from inner atmosphere film weight *To prevent electrical shock or damage to equipment , when the cover is removed , ensure the power supply is switched off. *Complete wiring and check the connections before applying power . Incorrect wiring may cause permanent damage to the unit.
8 . Bracket Dimension ( mm )
9 . System Check After proper installation and adjustment of the control , running at least one full cycle of the equipment should check the system . If anything appears to operate incorrectly , the wiring and components should be rechecked.