Products
Ulp 4040 8040 Industrial Reverse Osmosis Membrane for RO System Manufacturer Factory Price
Ulp 4040 8040 Industrial Reverse Osmosis Membrane for RO System Manufacturer Factory Price
Ulp 4040 8040 Industrial Reverse Osmosis Membrane for RO System Manufacturer Factory Price
Ulp 4040 8040 Industrial Reverse Osmosis Membrane for RO System Manufacturer Factory Price
Ulp 4040 8040 Industrial Reverse Osmosis Membrane for RO System Manufacturer Factory Price
Ulp 4040 8040 Industrial Reverse Osmosis Membrane for RO System Manufacturer Factory Price
Ulp 4040 8040 Industrial Reverse Osmosis Membrane for RO System Manufacturer Factory Price
Ulp 4040 8040 Industrial Reverse Osmosis Membrane for RO System Manufacturer Factory Price

Ulp 4040 8040 Industrial Reverse Osmosis Membrane for RO System Manufacturer Factory Price

FOB Reference Price: Get Latest Price
≥100 Pieces
US $44.2
Free Inquiry
Customized Request
  • Product Details
  • {{item.text}}

Quick Details

Weight:
3KG
Productivity:
2400GPD
Weight (KG):
3 kg
Product name:
Industrial Reverse Osmosis Membrane
Appliaction:
RO Plants, Chemical Factory, Food & Beverage
Certificate:
ISO9001, ROHS, CE
Origin:
China
Salt rejection:
99.3%
Water output:
2400GPD
Test pressure:
150PSI
Test temperature:
25℃
Package:
1PCS/CTN
Customization:
OEM/ODM

Quick Details

Core Components:
None
Place of Origin:
Guangdong, China
Brand Name:
Hikins
Weight:
3KG
Productivity:
2400GPD
Weight (KG):
3 kg
Product name:
Industrial Reverse Osmosis Membrane
Appliaction:
RO Plants, Chemical Factory, Food & Beverage
Certificate:
ISO9001, ROHS, CE
Origin:
China
Salt rejection:
99.3%
Water output:
2400GPD
Test pressure:
150PSI
Test temperature:
25℃
Package:
1PCS/CTN
Customization:
OEM/ODM
Product Description

Model No., ULP-4040

Series, ULP 2000ppm

Active area, 85(7.9) Ft2(m2)
Removal rate, 99.3%
Water output, 2400(9.1) GPD(m3/d)
Testing pressure, 150PSI
Test temperature, 25ºC

Series Model Active area Salt rejection Water output Test pressure
Ft2(m2) % GPD(m3/d) PSI (Mpa)
ULP
2000ppm
ULP-2521 13(1.2) 99 370(1.4) 150(1.05)
ULP-2540 28(2.6) 99 800(3.0)
ULP-3020 24(2.2) 99 420(1.6)
ULP-4021 36(3.3) 99 1000(3.8)
ULP-4040S 81(7.5) 99.3 2400(9.1)
ULP-4040 85 (7.9) 99.3 2400 (9.1)
ULP-4040P 93(8.6) 99.4 2500(9.5)
ULP-4040M 103 (9.6) 99.5 2600(9.8)
ULP-8365 365(34) 99.5 10000(38)
ULP-8400 400(37) 99.5 11000(41)
ULP-8440 440(41) 99.5 12000(45)
ULP-8040HF 480 (44.7) 99.5 13000 (49)
ULP-8040FR 335 (31) 99.5 9500 (36)
LP
5000ppm
LP-2521 13(1.2) 99.3 350(1.3) 225(1.55)
LP-2540 28(2.6) 99.3 750(2.8)
LP-3020 26(2.4) 99.3 600(2.4)
LP-4021 36(3.3) 99.3 900(3.4)
LP-4040 85(7.9) 99.5 2400 (9.1)
LP-4040P 93(8.6) 99.5 2500(9.5)
LP-4040M 103 (9.6) 99.5 2600(9.8)
LP-4040FR 85(7.9) 99.5 2400(9.0)
LP-8365 365(34) 99.5 10000(38)
LP-8400 400(37) 99.5 11000(41)
LP-8440 440(41) 99.5 12000(45)
LP-8040HF 480 (44.7) 99.5 13000 (49)
LP-8400FR 400 (37.2) 99.5 10500 (39.7)
XLP
500ppm
XLP-2521 13(1.2) 99 500(1.9) 100(0.69)
XLP-2540 28(2.6) 99 1100(4.2)
XLP-3020 24(2.2) 99 550(2.1)
XLP-4021 36(3.3) 99 1300(4.9)
XLP-4040 88(8.2) 99.2 2600(9.8)
XLP-8440 440(41) 99.2 13000(49)
HS
20000ppm
HS-4040 75(7.0) 98.5 1800(6.8) 320(2.21)
HS-8400 320(29.8) 98.5 7300(27.6)
SW
40000PPM
SW-2521 12(1.1) 99.2 200(0.76) 800(5.52)
SW-2540 28(2.6) 99.2 500(1.89)
SW-4021 33 (3.1) 99.2 750(2.8)
SW-4040 85(7.9) 99.5 1400(5.3)
SW-8400 380(35.2) 99.8 6000(22.7)

Packaging & Shipping

How To Install

Our Advantages

  • TUV and SGS Verified Factory supports OEM & ODM services
  • 10+ Years of Experience in RO Membranes and Water Purification
  • 113+ Patents, and highly comply with ISO, RoHS, and CE Certificates
  • 36000 square meter Production Area with a Production Capability of 10000 Units Monthly
  • Professional Laboratory of Quality Control and Testing
  • 1-year Warranty And Whole Lifetime Service
  • Customers cover more than 50 global countries and areas
Hikins Workshop

HIKINS Group, one of the most famous manufacturers of RO systems in China, has its solely owned industrial membrane manufacturing factory with 36000 square meters located in Dongguan city , where all scope of the membrane is manufactured, including Reverse Osmosis (RO) membrane, Nanofiltration (NF) membrane, Ultrafiltration (UF) membrane, pressure tank and diaphragm pumps, full range of BW series brackish water desalination, LP series Low-pressure RO membrane, FR series fouling resistant brackish water RO membrane, and SW series seawater desalination RO membrane, etc.

As one of the trademark brands of the Hikins group, Hallowway brand membranes have been widely adopted in China, such as China municipal water supply projects, electricity generating companies, chemical and electrical companies, pharmaceutical companies, food and drinks industries, drinking water industries, etc. At the same time, HALLOWWAY products also have been widely sold to North America, Europe, the Middle East, and Southeast Asia, serving millions of users worldwide.


Hikins upholds the principle of business integrity and professionalism and keeps its product with innovative technology to provide good quality products and good service to our customers all over the world.

Certifications

Exhibition Show

FAQ

FAQs on Reverse Osmosis RO Membrane OEM Manufacturing

Q1: What type of RO membrane is available in your company?

A1: In general, Hikins has Domestic RO membranes and Industrial RO membranes. For Domestic RO membranes, Hikins has Municipal Tap water RO membranes, Rural Area Under Ground water RO membranes, High-flow Low-pressure RO membranes, and Brackish water RO membranes. For Industrial RO membranes, Hikins has Low-Pressure energy-saving RO membranes, BW Brackish water desalination RO membranes, FR Fouling Resistant RO membranes, as well as XLE Extreme Low-Pressure RO membranes, and High Salinity Brackish Water Desalination RO membranes.

Q2: What is the Salt Rejection Ratio?

A2: The Salt rejection describes the quality of salt removed from the Reverse Osmosis feed water stream as a percentage. It's one of the key elements of the RO membrane quality, however, other essential elements such as RO membrane performance durability, stability, application scope in different regions, and permeate flow output at the same pressure will all be the important factors to judge the quality of the membrane.

Q3: Is the Salt ratio of the RO membrane the higher the better?

A3: This will depend on the feed water quality, if the feed water quality is good, even a 90% salt rejection membrane will be workable, if the feed water is of bad quality and with a brackish water environment, a higher salt rejection above 95% is an ideal choice. Any membrane that meets the local drinking water standard will be good.

Q4: Is there are any other elements we need to take into consideration when selecting the RO membrane?

A4: Yes, the pre-treatment filter cartridge and the pre-treatment system will affect the RO membrane performance as well, please select good quality filters and pre-treatment system.

Q5: Why there are white foam-like water being in the treated water at the initial usage?

A5: To preserve the RO membrane for a long shelf-life, and prevent the membrane from being oxidized, a water-soluble protection material is coated on the surface of the membrane, which will be rejected in both the rejected water and treated water, for initial use, both rejected water and treated water should be rejected and the RO membrane should be thoroughly cleaned. The treated water at initial use shall not be injected into the water storage tank.

Q6: Why are there bubbles in the treated water?

A6: Oxygen nitrogens and carbon dioxide are water soluble in the molecular form, during the water filtration process in the Reverse Osmosis process, the air will be released due to the pressure change between input water and output water. The air is not harmful, just like Coca-Cola.

Q7: Why does dry RO membrane have a salt rejection rising process from its initial usage?

A7: The performance of the RO membrane is strictly connected to the wetness of the membrane, when the membrane is wet, it will reach its maximum performance, the dry membrane has a process to become wet from its initial usage. Make sure that the membrane should be rinsed after each usage.

Q8: Why active carbon filter is requested for RO membranes?

A8: Chloride and chlorine content is harmful from the feed water, RO membrane is easy to be damaged as the surface of the RO membrane will easily be oxidized.

APP
Post My RFQ
WhatsApp
+86-17326049340