- Product Details
- {{item.text}}
Quick Details
-
Weight:
-
350kg
-
Size:
-
1870*650*1850mm
-
Power:
-
2.5kw
-
Weight (KG):
-
350 kg
-
Certificate:
-
CE &ISO
-
Desalination rate:
-
97% - 99%
-
Recovery rate:
-
50% - 75%
-
Type of control:
-
automatic/manual/semi-auto
-
Voltage:
-
110V 220V 380V 480V / 50 Hz 60Hz or customized
-
high pressure pump:
-
Nanfang CNP pump
-
Application:
-
drinking water,food process,lab and so on
-
Feed water:
-
Bore well/City tap/River/Rain Water...
-
Keywords:
-
house water purification system
-
Filter Media:
-
Quartz sand + Activated carbon + Water softener + Security filter + RO
Quick Details
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
Kaiyuan
-
Material:
-
Wooden case
-
Weight:
-
350kg
-
Size:
-
1870*650*1850mm
-
Power:
-
2.5kw
-
Weight (KG):
-
350 kg
-
Certificate:
-
CE &ISO
-
Desalination rate:
-
97% - 99%
-
Recovery rate:
-
50% - 75%
-
Type of control:
-
automatic/manual/semi-auto
-
Voltage:
-
110V 220V 380V 480V / 50 Hz 60Hz or customized
-
high pressure pump:
-
Nanfang CNP pump
-
Application:
-
drinking water,food process,lab and so on
-
Feed water:
-
Bore well/City tap/River/Rain Water...
-
Keywords:
-
house water purification system
-
Filter Media:
-
Quartz sand + Activated carbon + Water softener + Security filter + RO
Ro Electrolytic Water Treatment Machine 500L 1000L Osmosis Reverse House Water Purification System
Product Paramenters
RO reverse osmosis system
Kaiyuan reverse osmosis water treatment equipment uses pretreatment device (quartz sand filter,
activated carbon, water softener, security filter) With RO reverse osmosis system multiple filtration
and separation of water ion technology, the salt removal rate can reach 97%-99%
Working Process Chart:
Raw water pump→ Quartz sand filter→ activated carbon filter→ Anti-scale dosing system→security filter → high pressure pump→Reverse osmosis system→UV → pure water tank
Function of every part:
1. Raw water pump-- provide the pressure to quartz sand filter/active carbon filter/ water softener
2. Sand filter-- get rid of turbidity, suspended matter
3. Active Carbon filter--Remove the color, free chloride, organic matter, harmful matter, ect.
4. Softener--exchange "ions" of calcium and magnesium with the most common and easiest method.
5. Security filter--prevent large particles into RO membrane, accuracy is 5um,
6. High pressure pump-- Provide the high pressure to RO membrane
7. RO system-- main part of the plant. The RO membrane's desalting rate can reach 97% and above, removing over 99% ions.
1. Raw water pump-- provide the pressure to quartz sand filter/active carbon filter/ water softener
2. Sand filter-- get rid of turbidity, suspended matter
3. Active Carbon filter--Remove the color, free chloride, organic matter, harmful matter, ect.
4. Softener--exchange "ions" of calcium and magnesium with the most common and easiest method.
5. Security filter--prevent large particles into RO membrane, accuracy is 5um,
6. High pressure pump-- Provide the high pressure to RO membrane
7. RO system-- main part of the plant. The RO membrane's desalting rate can reach 97% and above, removing over 99% ions.
Mode
|
KYRO-1000
|
Production capacity
|
1000L/H
|
Power
|
About 2.5 KW
|
RO membrane
|
USA RO membrane 4040
|
Voltage
|
110V 220V 380V 480V / 50 Hz 60Hz or customized
|
Desalination rate
|
97% - 99%
|
Recovery rate
|
50%-70%
|
Material
|
FRP,SUS,PVC
|
Certificate
|
CE&ISO9001
|
Warranty
|
One year
|
Every part of the reverse osmosis system
S/N.
|
Commodity name
|
Application
|
1
|
Raw water tank
|
Store water, buffering pressure, overcome instability of supplying water by pipe, ensure to supply water stably and continuously
for whole system. (Customer provide for themselves, because big size will result in expensive freight.) |
2
|
Raw water pump or called booster pump
|
Provide needed pressure for every pretreatment filter
|
3
|
Mechanical filter or called quartz sand filter or sand filter
|
We use fiber glass or stainless steel vessel as housing, fill quarts sand, it can filter big particles impurities, suspended
substances, colloids etc. |
4
|
Activated carbon filter
|
We use fiber glass or stainless steel vessel as housing, fill activated carbon, remove color, odor, residual chlorine and organics
substances. |
5
|
Water softener, demineralizer, or called Na+ exchanger
|
Adopt cation resin to soften water, cation resin will absorb Ca2+, Mg2+(main elements for composing scale), reduce hardness of raw water, System can make resin intelligently regenerate, recycling
|
6
|
Security filter or pp filter, or called PP sediment filter
|
prevent large particles, bacteria, viruses into RO membrane, accuracy is 5µm,
|
7
|
|
Provide needed working pressure for RO system, ensure production capacity of pure water. (CNP pump or custom other brand)
|
8
|
RO(reverse osmosis) system
|
Can remove particles, colloids, organic impurities, heavy metal ions, bacteria, virus, heat source etc. harmful substances and 99%
dissolved salts. (RO membranes USA Filmtec) |
Products Description
Laser engraving to customize your logo company and language, Simple operation, real-time display of data, monitoring of equipment working conditions
Label each wire and synchronize engineering drawings for easy operation, 4 independent air switches + 2 fuses, 6-fold safety protection, the equipment is more durable
High pressure pump CNP pump, The famous pump brand in China.It is to provide the pressure for water into ro membrane.It is the improtant part in the system
Laser engraving to customize your logo company and language,MOQ 1set,
Our craft, Single-sided welding, double-sided molding,no dead -angle, won't leak water and grow bacteria
How long the consumables should be replaced?
All the consumable replace period will be depend on the feed water quality.
PP filter cartridge
Advice Replacement time: every month
Quartz sand
Advice Replacement time: Every 15 - 18 months
Activated Carbon
Advice Replacement time: Every 15 - 18 months
Resin
Advice Replacement time: Every 15 - 18 months
RO membrane (LCLE4040)
Advice Replacement time:
Every 2 years
Every 2 years
UV lamp
Advice Replacement time:
9000 hours
9000 hours
Certifications
Contact US
Hot Searches