Products
ABC 6kg Dry Powder Fire Extinguisher/CO2 Car Foam Fire Extinguisher
ABC 6kg Dry Powder Fire Extinguisher/CO2 Car Foam Fire Extinguisher
ABC 6kg Dry Powder Fire Extinguisher/CO2 Car Foam Fire Extinguisher
ABC 6kg Dry Powder Fire Extinguisher/CO2 Car Foam Fire Extinguisher
ABC 6kg Dry Powder Fire Extinguisher/CO2 Car Foam Fire Extinguisher
ABC 6kg Dry Powder Fire Extinguisher/CO2 Car Foam Fire Extinguisher
ABC 6kg Dry Powder Fire Extinguisher/CO2 Car Foam Fire Extinguisher
ABC 6kg Dry Powder Fire Extinguisher/CO2 Car Foam Fire Extinguisher

ABC 6kg Dry Powder Fire Extinguisher/CO2 Car Foam Fire Extinguisher

FOB Reference Price: Get Latest Price
≥100 Pieces
US $4.1
≥500 Pieces
US $3.7
≥1000 Pieces
US $2.8
Free Inquiry
Customized Request
  • Product Details
  • {{item.text}}

Quick Details

Name:
Fire extinguisher
Cylinder Material:
ST12,DC01
Temperature range:
-30~+60℃
Max working pressure:
14bar
Test pressure:
25bar
Spray time:
≥8 s Fire Extinguisher
Pressure to run:
1.2 N (Mpa)
Painting::
Red
Product name:
Portable Dry Chemical Powder Fire Extinguisher
MOQ:
100

Quick Details

Place of Origin:
Fujian, China
Brand Name:
Minshan
Model Number:
MS-FE
Name:
Fire extinguisher
Cylinder Material:
ST12,DC01
Temperature range:
-30~+60℃
Max working pressure:
14bar
Test pressure:
25bar
Spray time:
≥8 s Fire Extinguisher
Pressure to run:
1.2 N (Mpa)
Painting::
Red
Product name:
Portable Dry Chemical Powder Fire Extinguisher
MOQ:
100
Product Description

Fire Extinguisher

Dry Chemical fire extinguishers extinguish the fire primarily by interrupting the chemical reaction of the fire triangle.Today's most widely used type of fire extinguisher is the multipurpose dry chemical that is effective on Class A, B, and C fires. This agent also works by creating a barrier between the oxygen element and the fuel element on Class A fires.Ordinary dry chemical is for Class B & C fires only. It is important to use the correct extinguisher for the type of fuel! Using the incorrect agent can allow the fire to re-ignite after apparently being extinguished succesfully.

1.Size List

NAME/TYPE

WEIGHT(kg)

VALID TIME TO SPRAY(s)

VALID DISTANCE TO SPRAY

PRESSURE TO DRIVE N (Mpa)

USING  TEMPURATURE °c

INSULATING QUALITY

LEVEL;TO;OUTFIRE;
MFZ/ABC1 1±5% ≥8 ; ≥3.0 ;-20~+55 ;5KV ;1A21B
MFZ/ABC2 2±3% ≥8 ; ≥3.0 ;1.2 -20~+55 5KV 1A21B
MFZ/ABC3 3±3% ≥13 ; ≥3.5 ; 1.2 ;-20~+55 ;5KV ;2A34B
MFZ/ABC4 4±2% ≥13 ≥3.5 ; 1.2 ;-20~+55 ;5KV ;2A55B
MFZ/ABC5 5±2% ≥13 ≥3.5 ; 1.2

-20~+55

5KV 3A89B
MFZ/ABC8 8±2% ≥15 ; ≥4.5 ; 1.2 -20~+55 5KV 4A144B

2.How  to use

1. Pull the Pin at the top of the extinguisher. The pin releases a locking mechanism and;will allow  you to discharge the extinguisher.

2. Aim at the base of the fire, not the flames. This is important - in order to put out the fire, you must extinguish the fuel.

3. Squeeze the lever slowly. This will release the extinguishing agent in the extinguisher. If the handle is  seleased, the discharge will stop.

4. Sweep from side to side. Using a sweeping motion, move the fire extinguisher back and forth until the fire is completely out. Operate the extinguisher from a safe distance, several feet away, and then move  towards the fire once it starts to diminish.

5. Be sure to have read the instructions on your fire extinguisher

ABC Dry powder fire extinguisher small fire extinguisheruisher

Dry Chemical fire extinguishers extinguish the fire primarily by interrupting the chemical reaction of the fire triangle.Today's most widely used type of fire extinguisher is the multipurpose dry chemical that is effective on Class A, B, and C fires. This agent also works by creating a barrier between the oxygen element and the fuel element on Class A fires.Ordinary dry chemical is for Class B & C fires only. It is important to use the correct extinguisher for the type of fuel! Using the incorrect agent can allow the fire to re-ignite after apparently being extinguished succesfully.

1.Size List

NAME/TYPE

WEIGHT(kg)

VALID TIME TO SPRAY(s)

VALID DISTANCE TO SPRAY

PRESSURE TO DRIVE N (Mpa)

USING  TEMPURATURE °c

INSULATING QUALITY

LEVEL;TO;OUTFIRE;
MFZ/ABC1 1±5% ≥8 ; ≥3.0 ;-20~+55 ;5KV ;1A21B
MFZ/ABC2 2±3% ≥8 ; ≥3.0 ;1.2 -20~+55 5KV 1A21B
MFZ/ABC3 3±3% ≥13 ; ≥3.5 ; 1.2 ;-20~+55 ;5KV ;2A34B
MFZ/ABC4 4±2% ≥13 ≥3.5 ; 1.2 ;-20~+55 ;5KV ;2A55B
MFZ/ABC5 5±2% ≥13 ≥3.5 ; 1.2

-20~+55

5KV 3A89B
MFZ/ABC8 8±2% ≥15 ; ≥4.5 ; 1.2 -20~+55 5KV 4A144B

2.How  to use

1. Pull the Pin at the top of the extinguisher. The pin releases a locking mechanism and;will allow  you to discharge the extinguisher.

2. Aim at the base of the fire, not the flames. This is important - in order to put out the fire, you must extinguish the fuel.

3. Squeeze the lever slowly. This will release the extinguishing agent in the extinguisher. If the handle is  seleased, the discharge will stop.

4. Sweep from side to side. Using a sweeping motion, move the fire extinguisher back and forth until the fire is completely out. Operate the extinguisher from a safe distance, several feet away, and then move  towards the fire once it starts to diminish.

5. Be sure to have read the instructions on your fire extinguisher

Products Image

Main Product

APP
Post My RFQ
WhatsApp
+86-17326049340