- Product Details
- {{item.text}}
Quick Details
-
Model Number:
-
GWS-P3000-DP240-24
-
Output:
-
DC 24V
-
Input:
-
AC100-240V
-
Output current:
-
10A
-
Frequency Range:
-
47Hz-63Hz
-
Input Current:
-
<4.40A @115VAC, <2.20A @ 230VAC
-
Operation TEMP / Humidity:
-
-20℃-65℃, 20%-90%RH No condensing
-
Storage TEMP / Humidity:
-
-40℃-85℃, 10%-95%RH No condensing
-
Certification:
-
CCC, CE, FCC, RoHS
-
Dimension:
-
135*121*40mm
-
Warranty:
-
1 year
Quick Details
-
Output Type:
-
DC
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
GWS
-
Model Number:
-
GWS-P3000-DP240-24
-
Output:
-
DC 24V
-
Input:
-
AC100-240V
-
Output current:
-
10A
-
Frequency Range:
-
47Hz-63Hz
-
Input Current:
-
<4.40A @115VAC, <2.20A @ 230VAC
-
Operation TEMP / Humidity:
-
-20℃-65℃, 20%-90%RH No condensing
-
Storage TEMP / Humidity:
-
-40℃-85℃, 10%-95%RH No condensing
-
Certification:
-
CCC, CE, FCC, RoHS
-
Dimension:
-
135*121*40mm
-
Warranty:
-
1 year
Product Description




Specification
Model
|
GWS-P3000-DP240-24
|
|
Output
|
|
|
Group of Output
|
1
|
|
DC Voltage
|
24VDC
|
|
Output Voltage Factory Setting
|
24.00-24.2VDC (Vin: 220VAC / Load: 0A)
|
|
Output Rated Current
|
10A
|
|
Output Current Range
|
0-10A
|
|
Rated Output Power
|
240W
|
|
Total Peak Output Power
|
360W (sustainable time 10S/220VAC)
|
|
Peak Output Current
|
15A (sustainable time 10S/220VAC)
|
|
Ripple Noise
|
Peak-to-peak value ≤100mV. (Measurement method: The terminal should be connected in parallel with 0.1uF and 47uF capacitors, and
the measurement should be performed at a bandwidth of 20MHz) |
|
Output Voltage Range
|
22.5-28VDC
|
|
Stabilized Voltage Precision
|
±1% (@ 90-264VAC input, 100% load)
|
|
Line Regulation
|
±0.5% (@ 90-264VAC input, 100% load)
|
|
Load Regulation
|
±1% (@90-264VAC input, 0-100% load)
|
|
Output Start Time
|
<2S @ nominal input (100% load )
|
|
Output Hold Time
|
>20ms @ 115VAC, >50 ms @ 230VAC (100% load )
|
|
Voltage Overshoot
|
≤5.0%
|
|
Input
|
|
|
Input Voltage Range
|
90-264VAC
|
|
Input Rated Voltage Range
|
100-240VAC
|
|
Frequency Range
|
47Hz-63Hz
|
|
Rated Frequency
|
50Hz/60Hz
|
|
Starting Voltage
|
90VAC
|
|
Efficiency
|
>90.0% @115VAC, >91.0% @ 230VAC
|
|
Input Current
|
<4.40A @115VAC, <2.20A @ 230VAC
|
|
Start Inrush Current
|
<35A @ 115VAC& 230VAC
|
|
Power Factor
|
>0.99 @ 115VAC, >0.93 @ 230VAC
|
|
Protection
|
|
|
Output Over Power
|
288-360W Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode:Swing machine,
Self-recovery after over-power released.) |
|
Output Over Voltage
|
28-29V Swing machine (Short circuit the Pin1-2 of U8, swing machine. Output recovery to normal after removing the short circuit)
Note: Do not use external voltage. |
|
Output Over Current
|
12-15A Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode:Swing machine,
Self-recovery after over-current released.) |
|
Output Short Circuit
|
Use a copper wire with a sufficient cross-sectional area and a length of 15cm±5cm to directly short-circuit at the power output
port, which can be short-circuited for a long time, and can be automatically restored after the short-circuit is eliminated. |
|
Operation Environment
|
|
|
Operation TEMP / Humidity
|
-40℃-70℃, 20%-95%RH No condensing
|
|
Storage TEMP / Humidity
|
-40℃-85℃, 10%-95%RH No condensing
|
|
Temperature Coefficient
|
±0.03%/℃ (0-50℃)
|
|
Vibration
|
Frequency range 10-500Hz, acceleration 2G, each sweep cycle 10min. 6 sweep cycles along the X, Y, and Z axes
|
|
Impact
|
Acceleration 20G, duration 11ms, 3 shocks along X, Y, and Z axis each
|
|
Altitude
|
2000m
|
|
Safety and Electromagnetic Compatibility Standard
|
|
|
Security Standard
|
GB4943/EN62368-1 ■Reference □Certification
|
|
Dielectric Strength
|
Input—Output: 3KVAC/10mA, Input--Case:1.5KVAC/10mA
Output---Case: 0.5KVDC/10mA , Time for each testing is 1min. |
|
Ground Test
|
Test conditions: 32A/2 minutes, Ground impedance: <0.1 ohms.
|
|
leakage Current
|
Input to ground ≤3.5mA, Input to output ≤0.25mA (Input 264VAC, Frequency 63Hz)
|
|
Insulation Resistance
|
Input-Output: 10M ohms
|
|
Conducted Disturbance
|
EN55022, EN55024, FCC PART 15 Class B
|
|
Radiated Interference
|
EN55022, EN55024, FCC PART 15 Class B
|
|
Harmaonic Current
|
EN61000-3-2 Class D
|
|
Conducted Disturbance
|
EN61000-4-6 Level 3
|
|
Radiation Harassment
|
EN61000-4-3 Level 3 Class B
|
|
Power Frequency Harassment
|
EN61000-4-8 Level 3
|
|
Static Harassment
|
EN61000-4-2 Level 4 Class B
|
|
fast Burst
|
EN61000-4-4 Level 4 Class B
|
|
Lightning Strike (Surge)
|
EN61000-4-5 Level 4 Class B
|
|
interrupted Fall
|
EN61000-4-11
|
|
Others
|
|
|
Dimension
|
131*121*45mm
|
|
Warranty
|
5 years
|
Hot Searches