Products
Input AC100-240V 2.3A Output DC 24V 10A 240W/24V Industrial DIN Rail Power Supply for Industrial Ethernet Switch
Input AC100-240V 2.3A Output DC 24V 10A 240W/24V Industrial DIN Rail Power Supply for Industrial Ethernet Switch
Input AC100-240V 2.3A Output DC 24V 10A 240W/24V Industrial DIN Rail Power Supply for Industrial Ethernet Switch
Input AC100-240V 2.3A Output DC 24V 10A 240W/24V Industrial DIN Rail Power Supply for Industrial Ethernet Switch
Input AC100-240V 2.3A Output DC 24V 10A 240W/24V Industrial DIN Rail Power Supply for Industrial Ethernet Switch
Input AC100-240V 2.3A Output DC 24V 10A 240W/24V Industrial DIN Rail Power Supply for Industrial Ethernet Switch
Input AC100-240V 2.3A Output DC 24V 10A 240W/24V Industrial DIN Rail Power Supply for Industrial Ethernet Switch
Input AC100-240V 2.3A Output DC 24V 10A 240W/24V Industrial DIN Rail Power Supply for Industrial Ethernet Switch

Input AC100-240V 2.3A Output DC 24V 10A 240W/24V Industrial DIN Rail Power Supply for Industrial Ethernet Switch

FOB Reference Price: Get Latest Price
≥10 Pieces
US $40.5
≥100 Pieces
US $34.8
Free Inquiry
Customized Request
  • Product Details
  • {{item.text}}

Quick Details

Model Number:
GWS-P3000-DP240-24
Output:
DC 24V
Input:
AC100-240V
Output current:
10A
Frequency Range:
47Hz-63Hz
Input Current:
<4.40A @115VAC, <2.20A @ 230VAC
Operation TEMP / Humidity:
-20℃-65℃, 20%-90%RH No condensing
Storage TEMP / Humidity:
-40℃-85℃, 10%-95%RH No condensing
Certification:
CCC, CE, FCC, RoHS
Dimension:
135*121*40mm
Warranty:
1 year

Quick Details

Output Type:
DC
Place of Origin:
Guangdong, China
Brand Name:
GWS
Model Number:
GWS-P3000-DP240-24
Output:
DC 24V
Input:
AC100-240V
Output current:
10A
Frequency Range:
47Hz-63Hz
Input Current:
<4.40A @115VAC, <2.20A @ 230VAC
Operation TEMP / Humidity:
-20℃-65℃, 20%-90%RH No condensing
Storage TEMP / Humidity:
-40℃-85℃, 10%-95%RH No condensing
Certification:
CCC, CE, FCC, RoHS
Dimension:
135*121*40mm
Warranty:
1 year
Product Description
Specification
Model
GWS-P3000-DP240-24
Output
Group of Output
1
DC Voltage
24VDC
Output Voltage Factory Setting
24.00-24.2VDC (Vin: 220VAC / Load: 0A)
Output Rated Current
10A
Output Current Range
0-10A
Rated Output Power
240W
Total Peak Output Power
360W (sustainable time 10S/220VAC)
Peak Output Current
15A (sustainable time 10S/220VAC)
Ripple Noise
Peak-to-peak value ≤100mV. (Measurement method: The terminal should be connected in parallel with 0.1uF and 47uF capacitors, and
the measurement should be performed at a bandwidth of 20MHz)
Output Voltage Range
22.5-28VDC
Stabilized Voltage Precision
±1% (@ 90-264VAC input, 100% load)
Line Regulation
±0.5% (@ 90-264VAC input, 100% load)
Load Regulation
±1% (@90-264VAC input, 0-100% load)
Output Start Time
<2S @ nominal input (100% load )
Output Hold Time
>20ms @ 115VAC, >50 ms @ 230VAC (100% load )
Voltage Overshoot
≤5.0%
Input
Input Voltage Range
90-264VAC
Input Rated Voltage Range
100-240VAC
Frequency Range
47Hz-63Hz
Rated Frequency
50Hz/60Hz
Starting Voltage
90VAC
Efficiency
>90.0% @115VAC, >91.0% @ 230VAC
Input Current
<4.40A @115VAC, <2.20A @ 230VAC
Start Inrush Current
<35A @ 115VAC& 230VAC
Power Factor
>0.99 @ 115VAC, >0.93 @ 230VAC
Protection
Output Over Power
288-360W Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode:Swing machine,
Self-recovery after over-power released.)
Output Over Voltage
28-29V Swing machine (Short circuit the Pin1-2 of U8, swing machine. Output recovery to normal after removing the short circuit)
Note: Do not use external voltage.
Output Over Current
12-15A Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode:Swing machine,
Self-recovery after over-current released.)
Output Short Circuit
Use a copper wire with a sufficient cross-sectional area and a length of 15cm±5cm to directly short-circuit at the power output
port, which can be short-circuited for a long time, and can be automatically restored after the short-circuit is eliminated.
Operation Environment
Operation TEMP / Humidity
-40℃-70℃, 20%-95%RH No condensing
Storage TEMP / Humidity
-40℃-85℃, 10%-95%RH No condensing
Temperature Coefficient
±0.03%/℃ (0-50℃)
Vibration
Frequency range 10-500Hz, acceleration 2G, each sweep cycle 10min. 6 sweep cycles along the X, Y, and Z axes
Impact
Acceleration 20G, duration 11ms, 3 shocks along X, Y, and Z axis each
Altitude
2000m
Safety and Electromagnetic Compatibility Standard
Security Standard
GB4943/EN62368-1 ■Reference □Certification
Dielectric Strength
Input—Output: 3KVAC/10mA, Input--Case:1.5KVAC/10mA
Output---Case: 0.5KVDC/10mA , Time for each testing is 1min.
Ground Test
Test conditions: 32A/2 minutes, Ground impedance: <0.1 ohms.
leakage Current
Input to ground ≤3.5mA, Input to output ≤0.25mA (Input 264VAC, Frequency 63Hz)
Insulation Resistance
Input-Output: 10M ohms
Conducted Disturbance
EN55022, EN55024, FCC PART 15 Class B
Radiated Interference
EN55022, EN55024, FCC PART 15 Class B
Harmaonic Current
EN61000-3-2 Class D
Conducted Disturbance
EN61000-4-6 Level 3
Radiation Harassment
EN61000-4-3 Level 3 Class B
Power Frequency Harassment
EN61000-4-8 Level 3
Static Harassment
EN61000-4-2 Level 4 Class B
fast Burst
EN61000-4-4 Level 4 Class B
Lightning Strike (Surge)
EN61000-4-5 Level 4 Class B
interrupted Fall
EN61000-4-11
Others
Dimension
131*121*45mm
Warranty
5 years
APP
Post My RFQ
WhatsApp
+86-17326049340