Products Description
128 Slice
CT Scanner
Computed Tomography System
1. Gantry
|
|
|
Aperture
|
76cm
|
|
One-button positioning
|
Preset 3 protocols
|
|
Scan speed/360°
|
0.48、0.5、 0.6、 0.7、0.8、 0.9、1.0、2.0s
|
|
Scan FOV
|
50cm
|
|
Tilt range
|
Mechanical tilt: ±30° (step 0.5°)
|
|
Display panel
|
Size: 13.3 inch LCD、showing current scan parameters
|
|
Auto voice
|
Support
|
|
ECG cable connection interface
|
Integrated in the front of gantry control panel
|
2. Patient Table
|
|
|
Max. horizontal travel range
|
1950mm
|
|
Horizontal scannable range
|
50mm~ 1860mm
|
|
Horizontal travel speed
|
1~ 200mm/s
|
|
Vertical table travel range
|
425mm~990mm
|
|
Max. table load
|
250kg
|
|
One-key patient table release
|
Support
|
|
Patient table cradle switches
|
Support
|
3. X-ray Tube
|
|
|
Anode heat capacity
|
5.3MHU
|
|
Cooling rate
|
815kHU/min
|
|
Focal spot size
|
Large: 1.0mm X 1.0mm
Small: 0.5mm X 1.0mm
|
4. Generator
|
|
|
Power rating
|
50.4kW
|
|
kV settings
|
70、80、100、120、 140kV
|
|
mA range (Step Size)
|
10~420mA (1mA step)
|
5.
Detector
|
|
|
Material
|
Solid-state GOS
|
|
No. of Detector rows
|
64 rows
|
|
Max. number of slices/rotation
|
128
|
|
No. of detector channels per row
|
864
|
|
Total No. of detector elements
|
55296
|
|
Min. slice thickness
|
0.625mm
|
|
Detector width
|
40mm
|
|
Max. data sampling rate
|
4800 views/360°
|
6. Scanning Performance
|
|
|
Scout scan
|
Supports 3 modes: A.P. lateral and dual;
Scannable range 50~1860mm;
|
|
Acquisition modes
|
128 X 0.625mm
64 X 0.625mm
32 x 0.625mm
|
|
Min slice thickness
|
0.625mm
|
|
Collimation width selection
|
40mm、20mm、15mm、 10mm
|
|
Pitch factor
|
0.2~1.75 (multiple selections)
|
|
Max. continuous scan time
|
100s
|
7. Image Reconstruction
|
|
|
Recon FOV
|
50~500mm;
50~650mm (Extended)
|
|
Recon matrices
|
512X512、768x 768、1024X1024
|
|
Recon speed
|
≥40 ips , the actual speed can reach 42~28 ips
|
|
Display matrix
|
1024 X 1024
|
8. Image Optimization Algorithm
|
|
|
Metal artifact reduction
|
Standard
|
|
Beam hardening artifact reduction
|
Standard
|
|
Partial volume artifact reduction
|
Standard
|
|
Steaking artifact reduction
|
Standard
|
|
Helical scan artifact reduction
|
Standard
|
|
Motion artifact reduction
|
Standard
|
9. Image Quality
|
|
|
Spatial resolution
|
≥21 lp/cm @ 0% MTF; X-Y plane
≥15 lp/cm@0% MTF; Z plane
|
|
Low-contrast resolution
|
2mm@0.3%@ 18mGy;
|
|
Image Noise
|
≤0.35% (Central dose≤40 mGy)
|
|
CT HU scale
|
Standard: -1024HU ~ +3072HU
Extended: -32768HU ~ +32767HU
|
10. Cardiac Scan
|
|
|
Prospective ECG scan
|
Support
|
|
Retrospective ECG scan
|
Support
|
|
Multi-sector coronary artery scan
|
Self-adaptive sector with maximum support for 4 sectors
|
|
Temporal resolution
|
60ms;
25ms @ RTF
|
|
ECG wave editing
|
Provides editing, adding, and deleting functions for abnormal ECGs (such as premature beat) used for coronary artery recon
|
|
Cardiac reconstruction
|
Automatically selects the optimal recon phase, multiphase recon for whole sequence or a single image
|
|
Instantaneous coronary artery freezing technology
RTF (Real Time Focus)
The third-generation motion artifact correction algorithm based on deep learning can model and compensate the heart motion artifact and partially eliminate artifacts caused by insufficient motion, breathing and temporal resolution. Displacement of the motion is corrected repeatedly through an iterative method to avoid excessive correction.
|
|