- Product Details
- {{item.text}}
Quick Details
-
Tube Current:
-
2MA
-
Filament Voltage:
-
3.5±0.2V
-
Filament Current:
-
3.7A
-
Focal spot size:
-
0.8MM
-
Inherent filtration:
-
0.8/mm Be,1.5mm glass
-
Target material:
-
Tungsten
-
Properties:
-
Non-medical x-ray tube
Quick Details
-
Place of Origin:
-
Henan, China
-
Brand Name:
-
HeBeiJin
-
Tube Voltage:
-
160KV
-
Tube Current:
-
2MA
-
Filament Voltage:
-
3.5±0.2V
-
Filament Current:
-
3.7A
-
Focal spot size:
-
0.8MM
-
Inherent filtration:
-
0.8/mm Be,1.5mm glass
-
Target material:
-
Tungsten
-
Properties:
-
Non-medical x-ray tube
Models 160 and 160A are the same product
Technical data Type:160
Property | Specification | Standard |
Nominal x-ray tube voltage | 160KV | IEC60613-2010 |
Operating tube voltage | 50-160KV | |
Max tube current | 2mA | |
Max anode input power | 320W | |
Max filament current | 3.7A | |
Filament voltage | 3.5±0.2V | |
Focal spot size | 0.8mm | EN12543-1999 |
Inherent filtration | 0.8/mm Be , 1.5-2.0mm glass | |
Target material | Tungsten | |
Axial maximum radiation
angle |
60° |
IEC/TR 60788-2004 |
Radial maximum radiation
angle |
80° |
|
Cooling method | Oil immersed(70 ℃ Max )and Convection oil cooling | |
Weight | 1100g |
Limits | Operation Limits |
Transport and Storage
Limits |
Ambient temperature
|
From 10°C to 70°C | From -40°C to 70°C |
Relative humidity
|
/ | From 10% to90% |
Barometric pressure
|
From 70kPa to106 kPa | From 50kPa to 106kPa |
We offer customized x ray tube as customer request