Quick Details
-
Model Number:
-
NPAs-9600
-
Place of Origin:
-
Zhejiang, China
-
Model:
-
NPAs-9600
-
Sample:
-
1-96
-
Sample Type:
-
Plasma, serum, whole blood, swab lotion, urine and other samples
-
Sample Channel Numbers:
-
1-4
-
Liquid Level Detection:
-
Capacitive-sensing level detection; pressure-sensing level detection
-
PCR Reagent Chamber:
-
Light-proofing design
-
PCR Consumables:
-
0.2mL single tube, 8-tube strips, and 96-well plates;
Quick Details
-
Warranty:
-
2 years
-
After-sale Service:
-
Return and Replacement
-
Brand Name:
-
Bioer
-
Model Number:
-
NPAs-9600
-
Place of Origin:
-
Zhejiang, China
-
Model:
-
NPAs-9600
-
Sample:
-
1-96
-
Sample Type:
-
Plasma, serum, whole blood, swab lotion, urine and other samples
-
Sample Channel Numbers:
-
1-4
-
Liquid Level Detection:
-
Capacitive-sensing level detection; pressure-sensing level detection
-
PCR Reagent Chamber:
-
Light-proofing design
-
PCR Consumables:
-
0.2mL single tube, 8-tube strips, and 96-well plates;
Product Description




Product name
|
Automatic Nucleic Acid Processing Workstatio
|
|
|
|
|
|
|||||
Model
|
NPAs-9600
|
|
|
|
|
|
|||||
Sample
|
1-96
|
|
|
|
|
|
|||||
Function
|
Identification of sample information and loading+ Nucleic acid extraction+ PCR reaction system set up
|
|
|
|
|
|
|||||
Principle
|
Magnetic bead extraction principle and rotary mixing technology
|
|
|
|
|
|
|||||
Magnetic bead recovery efficiency rate
|
≥99%
|
|
|
|
|
|
|||||
Sample Type
|
Plasma, serum, whole blood, swab lotion, urine and other samples
|
|
|
|
|
|
|||||
Sample Channel Numbers
|
1-4
|
|
|
|
|
|
|||||
Detection path
|
Pipette
|
Volume
|
Accuracy R
|
CV
|
F5
|
F6
|
|||||
|
50μL
|
50μL
|
2.0%
|
0.75%
|
CY5.5
|
Customized
|
|||||
|
1000μL
|
1000μL
|
1.0%
|
0.75%
|
|
|
|||||
Liquid Level Detection
|
Capacitive-sensing level detection; pressure-sensing level detection
|
|
|
|
|
|
|||||
Sample Tube Specifications
|
Compatible with various specifications of blood sample collection tubes, 5ml and 10ml sample tubes
|
|
|
|
|
|
|||||
|
2 steps: pyrolysis & elution,Temperature control: room temperature to 120 °C.
|
|
|
|
|
|
|||||
PCR Reagent Chamber
|
Light-proofing design
|
|
|
|
|
|
|||||
PCR Consumables
|
0.2mL single tube, 8-tube strips, and 96-well plates;
|
|
|
|
|
|
|||||
|
UV light sterilization units for the experimental and extraction cabinets
|
|
|
|
|
|
|||||
Information Technology
|
Multiple sample barcodes are scanned one by one during sample rack loading.
|
|
|
|
|
|
|||||
Size and Weight
|
Doors open:1400mm x 700mm x 1980mm (L*W*H)
|
|
|
|
|
|
|||||
Temperature control mode
|
Doors close:1400mm x 700mm x 1670mm (L*W*H)
|
|
|
|
|
|