- Product Details
- {{item.text}}
Quick Details
-
Model Number:
-
SJW
-
Output Frequency:
-
500W~7KW
-
Size:
-
495*365*220~700*485*265mm
-
Weight:
-
10~36kg
-
Application:
-
Home Appliance
-
Color:
-
Grey
-
Waveform:
-
Pure Sine Wave
-
Efficiency:
-
95%
-
Warranty:
-
12 Months
-
Display:
-
LCD
-
Protection:
-
Short circuit Overload etc.
-
Rated power:
-
6000w
-
OEM:
-
Accepted
-
Product name:
-
48V 96V Inverter Hybrid
-
Certificate:
-
CE RoHS
Quick Details
-
Output Current:
-
Optional
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
Xindun
-
Model Number:
-
SJW
-
Output Frequency:
-
500W~7KW
-
Size:
-
495*365*220~700*485*265mm
-
Weight:
-
10~36kg
-
Application:
-
Home Appliance
-
Color:
-
Grey
-
Waveform:
-
Pure Sine Wave
-
Efficiency:
-
95%
-
Warranty:
-
12 Months
-
Display:
-
LCD
-
Protection:
-
Short circuit Overload etc.
-
Rated power:
-
6000w
-
OEM:
-
Accepted
-
Product name:
-
48V 96V Inverter Hybrid
-
Certificate:
-
CE RoHS
- Pure sine wave output.
- Low frequency toroidal transformer lower loss.
- Brand new wide LCD screen, clearly and precisely shows working data.
- Three -stage charging: Constant current , constant voltage, float charge.
-
Three types working modes; Battery type selectable.
- Added fault code query function, easy to monitor the operation in real time.
-
Supports RS232 or RS485 communication port.
- Built in MPPT/PMW controller.
Specification | |||||||||||
Model SJW | 50112/24 | 70112/24 | 10212/24 | 15224/48 | 20224/48 | 30224/48 | 40248/96 | 50248/96 | 60248/96 | 70296 | |
Rated Power | 500W | 700W | 1000W | 1500W | 2000W | 3000W | 4000W | 5000W | 6000W | 7000W | |
Peak Power(20ms) | 1500W | 2100W | 3000W | 4500W | 6000W | 9000W | 12000W | 15000W | 18000W | 21000W | |
Start Motor | 0.5HP | 0.5HP | 1HP | 1.5HP | 2HP | 3HP | 3HP | 4HP | 4HP | 5HP | |
Battery Voltage | 12/24VDC | 24/48VDC | 48/96VDC | 96VDC | |||||||
Size(L*W*Hmm) | 408*296*130 | 540*380*150 | 620*400*181 | ||||||||
Packing Size(L*W*Hmm) | 495*365*220 | 645*455*235 | 700*485*265 | ||||||||
N.W.(kg) | 8.5 | 9.5 | 10.5 | 14 | 17 | 20 | 25 | 26 | 30 | 34 | |
G.W.(kg)(Carton Packing) | 10 | 11 | 12 | 16 | 19 | 22 | 27 | 28 | 32 | 36 | |
Installation Method | Wall-Mounted | ||||||||||
Parameter | |||||||||||
Input | DC Input Voltage Range | 10.5-15VDC(Single battery voltage) | |||||||||
AC Input Voltage Range | 73VAC~138VAC / 145VAC~275VAC | ||||||||||
AC Input Frequency Range | 45Hz~65Hz | ||||||||||
Max AC charging current | 6A~15A(Depending on the model) | ||||||||||
AC charging method | Three-stage (constant current, constant voltage, floating charge) | ||||||||||
Output | Efficiency(Battery Mode) | ≥85% | |||||||||
Output Voltage(Battery Mode) | 110VAC±2% / 220VAC±2% | ||||||||||
Output Frequency(Battery Mode) | 50/60Hz±1% | ||||||||||
Output Wave(Battery Mode) | Pure Sine Wave | ||||||||||
Efficiency(AC Mode) | >99% | ||||||||||
Output Voltage(AC Mode) | 110VAC±10% / 220VAC±10% | ||||||||||
Output Frequency(AC Mode) | Tracking Automatically | ||||||||||
Output waveform distortion
(Battery Mode) |
≤3%(Linear load) | ||||||||||
No load loss(Battery Mode) | ≤0.8% rated power | ||||||||||
No load loss(AC Mode) | ≤2% rated power( charger does not work in AC mode) | ||||||||||
No load loss(Energy saving Mode) | ≤10W | ||||||||||
Battery Type
(selectable) |
LEAD | Charge Voltage:14V;Float Voltage:13.8V(12V system; 24V system x2; 48V system x4; 96V system x8) | |||||||||
OP-LE | Charge Voltage:14.2V; Float Voltage:13.8V(12V system; 24V system x2; 48V system x4; 96V system x8) | ||||||||||
LITHIUM | Charge Voltage: 12.6V(NMC battery 3S) (12V system; 24V system x2; 48V system x4; 96V system x8) | ||||||||||
Customize battery | Charge and discharge parameters of different types of batteriescan be customized according to user requirements | ||||||||||
Protection | Battery undervoltage alarm | 11V; LITHIUM 9.5V(NMC battery 3S)(12V system; 24V system x2; 48V system x4; 96V system x8) | |||||||||
Battery undervoltage protection | 10.5V; LITHIUM 9V(NMC battery 3S)(12V system; 24V system x2; 48V system x4; 96V system x8) | ||||||||||
Battery overvoltage alarm | Lead acid battery: 15V(12V system; 24V system x2; 48V system x4; 96V system x8) | ||||||||||
Battery overvoltage protection | Lead acid battery: 17V(12V system; 24V system x2; 48V system x4; 96V system x8) | ||||||||||
Battery overvoltage recovery voltage | Lead acid battery: 14.5V(12V system; 24V system x2; 48V system x4; 96V system x8) | ||||||||||
Overload power protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | ||||||||||
Inverter output short circuit protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | ||||||||||
Temperature protection | >90°C(Shut down output) | ||||||||||
Alarm | A | Normal working condition, buzzer has no alarm sound | |||||||||
B | Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection | ||||||||||
C | When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal | ||||||||||
Inside Solar controller
(Optional) |
Charging Mode | PWM | MPPT or PWM | ||||||||
Charging current | 10A/20A/30A | 12V/24V/48V System:10A/20A/30A/40A/50A/60A; 96V System: 50A | |||||||||
PV Input Voltage Range |
PWM: 15V-44V(12V system);30V-44V(24V system);60V-88V(48V system); 120V-176V(96V system)
MPPT: 15V-120V(12V system);30V-120V(24V system);60V-120V(48V system) |
||||||||||
Max PV Input Voltage(At 25℃) | PWM: 50V(12V/24V system ); 100V(48V system ); 200V(96V system) / MPPT: 150V(12V/24V/48 system) | ||||||||||
PV Array Maximum Power |
12V system: 140W/280W/420W/560W/700W/840W; 24V system: 280W/560W/840W/1120W/1400W/1680W;
48V system: 560W/1120W/1680W/2240W/2800W/3360W; 96V system: 5.6KW |
||||||||||
Standby loss | ≤3W | ||||||||||
Maximum conversion efficiency | >95% | ||||||||||
Working Mode | Battery First/AC First/Saving Energy Mode | ||||||||||
Transfer Time | ≤4ms | ||||||||||
Display | LCD | ||||||||||
Thermal method | Cooling fan in intelligent control | ||||||||||
Communication | RS232/RS485(Optional) | ||||||||||
Environment | Operating temperature | -10℃~40℃ | |||||||||
Storage temperature | -15℃~60℃ | ||||||||||
Noise | ≤55dB | ||||||||||
Elevation | 2000m(More than derating) | ||||||||||
Humidity | 0%~95% ,No condensation | ||||||||||
Warranty | 1 year | ||||||||||
Note: All specifications are subject to charge without prior notice |
1. Battery number and capacity should be configured according to the rated voltage of the solar power system or invertor;
2. We offer 3 optional working modes (transfer time≤4ms):
01 Grid priority mode:
When the grid and battery are connected to the invertor, grid will supply power to the loads directly after voltage being stabilized and charge batteries via invertor. When the grid is cut off, the battery will automatically continue to supply power via invertor.
02 Energy saving mode:
If the power of the connected AC loads is lower than 5% of the invertor’s rated power, there will be no output from the invertor. Only the chip of invertor is working. The power consumption of the invertor is only 1~6W. The LCD shows the output voltage 0. If the power of the connected loads is over 5%, within 5S the invertor will automatically convert DC to AC to supply power for the loads . The LCD shows the output voltage.
03 Battery priority mode:
When the grid and battery are connected to the invertor, battery will supply power to the loads first. When battery capacity is not enough, the grid will continue to supply power automatically.
Package
Carton Box for packaging, or Wooden Box advised for Samples to protect in transportations.
Shipping
1. Fedex/ DHL/ TNT/ UPS for samples, door-to-door.
2. By air or by sea for batch goods, for CFL, Air port/ Port receiving.
3. Customers specifying freight forwarders or negotiable shipping methords.
4. Delivery time: 7 days for samples; 10 to 25 days for batch goods.
Payment | ||
T/T | EXW | 30% T/T in advance, balance paid before dispatch |
FOB | ||
CNF(CFR) | 30% T/T in advance, balance paid against copy of B/L | |
CIF | ||
L/C, D/A, D/P, Money Gram, Western Union, Paypal (Optional) |