- Product Details
- {{item.text}}
Quick Details
-
Measuring range:
-
(10~35)°C
-
Resolution:
-
0.001 K
-
Measurement accuracy:
-
± 60J/g
-
Repeatability error:
-
≤0.2% (Grade C)
-
Pressure endurance of oxygen bomb:
-
20 MPa
-
Ambient temperature:
-
10 °C~28 °C
-
Relative humidity:
-
≤85%
-
Power supply:
-
AC 220V±5%, 50 Hz, Customizable
-
Dimension:
-
600mm*480mm*460mm
Quick Details
-
Power:
-
Electronic
-
Place of Origin:
-
Chongqing, China
-
Heat capacity:
-
14000 J/K~15000 J/K
-
Measuring range:
-
(10~35)°C
-
Resolution:
-
0.001 K
-
Measurement accuracy:
-
± 60J/g
-
Repeatability error:
-
≤0.2% (Grade C)
-
Pressure endurance of oxygen bomb:
-
20 MPa
-
Ambient temperature:
-
10 °C~28 °C
-
Relative humidity:
-
≤85%
-
Power supply:
-
AC 220V±5%, 50 Hz, Customizable
-
Dimension:
-
600mm*480mm*460mm
Calorimetry Analyzer/Bomb Calorimeter Price
The Oxygen Bomb Calorific Value Tester is designed and made as per the national standard of People’s Republic of China GB/T213-2008 Test Method for Calorific Value of coal, GB/T384-1988 Test Method for Calorific Value of Petroleum Products and Calibration Regulation of People’s Republic of China JJG672-2001 Oxygen Bomb Calorimeter, as well as Shanghai enternprise standard Q/YXYY 10 XRY Series Oxygen Bomb Calorimeter.
Application
The instrument can be used to measure calorific value of flammable substances such as coal, coke, paraffin and other petroleum products(gasoline, jet fuel, diesel, etc.)
Main Technical Features
1.The instrument adopts technology of single chip microcomputer, LCD screen, high accuracy temperature sensor and high performance A/D conversion device. It is a highly intelligent instrument.
2.The test procedure is fully automatic. After placing sample and inputting right parameters, the instrument will finish all the procedures without manual interference. It will print the test data directly after test is over.
3.This instrument adopts sealed oxygen bomb. The whole structure adopts stainless steel material.The strength is enough to resist 20MPa hydrostatic test under room temperature.
Main T echnical S pecifications
Heat capacity |
14000 J/K~15000 J/K |
Measuring range |
(10~35)°C |
Resolution |
0.001 K |
Measurement accuracy |
± 60J/g |
Repeatability error |
≤0.2% (Grade C) |
Pressure endurance of oxygen bomb |
20 MPa |
Ambient temperature |
10 °C~28 °C |
Relative humidity |
≤85% |
Power supply |
AC 220V±5%, 50 Hz , Customizable |
Dimension |
600mm×480mm×460mm |
Structure
Details
Plug
two types of plug to choose
Accessories
We have other Bomb Calorimeters
0.0001C Fully Automatic Oxygen Bomb Calorimeter BLS-240F
0.001C LCD Oxygen Bomb Calorimeter BLS-240A