- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
HBYB
-
Model Number:
-
HBRD
-
Suitable for Medium:
-
Liquid, solid powder
-
Product name:
-
radar level meter
-
Measuring Range:
-
30 meters
-
Explosion-proof Grade:
-
Exib IIC T6 Gb/Exd IIC T6 Gb
-
Process Temperature:
-
(-40~250)℃
-
Application:
-
Liquid and solid powder measure,complicated process conditions
-
Measurement Precision:
-
±10mm
-
The signal Output:
-
(4 ~ 20) mA/HART
-
Process Pressure:
-
(-0.1~4)MPa
-
Color:
-
Yellow/blue
Quick Details
-
Grade:
-
Industrial
-
Warranty:
-
1 years
-
Place of Origin:
-
Henan, China
-
Brand Name:
-
HBYB
-
Model Number:
-
HBRD
-
Suitable for Medium:
-
Liquid, solid powder
-
Product name:
-
radar level meter
-
Measuring Range:
-
30 meters
-
Explosion-proof Grade:
-
Exib IIC T6 Gb/Exd IIC T6 Gb
-
Process Temperature:
-
(-40~250)℃
-
Application:
-
Liquid and solid powder measure,complicated process conditions
-
Measurement Precision:
-
±10mm
-
The signal Output:
-
(4 ~ 20) mA/HART
-
Process Pressure:
-
(-0.1~4)MPa
-
Color:
-
Yellow/blue
Product Parameter
Measurement principle
The measuring instrument sends short radar pulses to the product under test through the antenna system, the surface of the product reflects the signal wave, and then the antenna system receives the returned signal information. The instrument calculates the liquid level based on the elapsed time of the radar pulse and the entered tank height.
Product Information
Advantage
Non-contact radar technology is characterized by a particularly high measurement accuracy. Measurements are not affected by fluctuations in product performance, nor by changes in process conditions such as temperature, pressure or high levels of dust. User-friendly adjustment without filling and emptying the container saves time.
Technical Specifications
|
|
|
|
|||
Housing:
|
Steel 316L
|
|
|
|||
|
Seal ring between housing and housing cover
|
Silicone
|
|
|||
|
view Point window on housing
|
Polycarbonate
|
|
|||
|
Ground terminal
|
Stainless Steel
|
|
|||
Power:
|
Two-wirc
|
standard version
|
(16~36) VDC
|
|||
|
|
Intrinsic safe version
|
(21.6~26.4) VDC
|
|||
|
|
Power consumption
|
max.22.5mA
|
|||
|
|
Ripple allowed
|
|
|||
|
|
—<100Hz
|
Uss<1V
|
|||
|
|
—(<100~<100K)Hz
|
Uss<10mV
|
|||
|
Four-wire/two
|
intrinsic safe+explosion proof
|
(21.6一26.4) VDC,
|
|||
|
-chamber
|
Power consumption
|
max.1VA,1W
|
|||
Cable:
|
Cable entry/plug
|
one cable entry of M20x1.5,one blind of M20x1.5
|
|
|||
|
Spring Connection terminal
|
Application for cables with cross section of2.5m㎡
|
|
|||
Output:
|
Output signal
|
4~-20mA/HART
|
|
|||
|
Resolution
|
1.6 μa
|
|
|||
|
Fault signal
|
Constant current output:20.5mA; 22mA; 3.9mA
|
|
|||
|
Integration time
|
0~50 seconds,adjustable
|
|
|||
|
Blind spot
|
end of antenna
|
|
|||
|
Max. measurement distance
|
10m
|
|
|||
|
Microwave frequency
|
26GHz
|
|
|||
|
Measurement interval
|
about 1 sec.(depend on parameter settings)
|
|
|||
|
Adjustment time
|
about 1 sec.(depend on parameter settings)
|
|
|||
|
Resolution on display
|
1mm
|
|
|||
|
Accuracy
|
see the diagram below
|
|
|||
|
Temperature for storage/transport
|
(-40~80)℃
|
|
|||
|
Process tempcrature (probe)
|
(-40~250)℃
|
|
|||
|
Relative humidity
|
<95%
|
|
|||
|
Pressure
|
Max.4MPa
|
|
|||
|
Vibration proof
|
mechanical vibration l0m/s3 ,(10~~150)Hz
|
|
Applicable Scenario
Certifications
Hot Searches