- Product Details
- {{item.text}}
Quick Details
-
Material:
-
Zinc alloy
-
Keypad size:
-
Keypad D120*T40 mm
-
Lock body size:
-
(without bolt): 84*60*28 mm
-
Bolt:
-
Deadbolt
-
Application:
-
Safe, vault, ATM
-
Manager mode:
-
1 manager code and 8 users
-
Changeable combinations:
-
Consist of 6-9 digits
-
Certification:
-
U.L. Type1, EN B, Vds 2, A2P B/E, DNV
-
Auto-relock:
-
Auto-relock after no operation for 4 seconds when opened.
-
Delivery time:
-
1-3 working days after confirm payment
Quick Details
-
Place of Origin:
-
United States
-
Brand Name:
-
Sargent & Greenleaf
-
Model Number:
-
SG6124
-
Material:
-
Zinc alloy
-
Keypad size:
-
Keypad D120*T40 mm
-
Lock body size:
-
(without bolt): 84*60*28 mm
-
Bolt:
-
Deadbolt
-
Application:
-
Safe, vault, ATM
-
Manager mode:
-
1 manager code and 8 users
-
Changeable combinations:
-
Consist of 6-9 digits
-
Certification:
-
U.L. Type1, EN B, Vds 2, A2P B/E, DNV
-
Auto-relock:
-
Auto-relock after no operation for 4 seconds when opened.
-
Delivery time:
-
1-3 working days after confirm payment
Sargent 6124 automatic electronic keypad digital combination lock
Dimension
: SG 6124
Keypad
: D120*T40 mm
Install
: D41 mm
Lock body
: 84*60*28 mm
Install
: 66*42 mm
Origin:
USA
Bolt
: Deadbolt
Material
: Zinc alloy
Certification
: U.L. Type1, EN B, Vds 2, A2P B/E, DNV
Application
: Safe, vault, ATM
Feature
:
1.Silent Alarm: Duress signal will be sent to alarm box if the duress combination is entered(last number of the combination either one number higher or lower), lock will still open without indication that duress signal has been sent to the alarm system(alarm box required).
2.Dual Mode: Two valid combinations from different user needed to open the lock at the same time.
3.Audit trail: Utilizing SG view software, last 512 events are captured with date and time stamp.
4.Manager mode: 1 manager code and 8 users
5.Time delay: Lock cannot be opened during the delay period(1-99 min)
6.Time delay override mode: Enables user 9 to override the time delay mode.
7.Wrong try penalty: 5 minutes penalty time after 4 consecutive invalid codes.
8.Low voltage signal: LED flashes and beeps when in low voltage.
9.Auto-relock: Auto-relock after no operation for 4 seconds when opened.
10.Changeable combinations: Consist of 6-9 digits
11.LED and beeping signal helps when operating
12.Combinations still memorized when replacing battery and could be checked on computer.