- Product Details
- {{item.text}}
Quick Details
-
Place of Origin:
-
Zhejiang, China
-
Brand Name:
-
CHINCAN
-
Model Number:
-
AA320N
-
Wavelength Range:
-
190-900
-
Spectrophotometer WL range:
-
190-900nm
-
Spectrophotometer WL accuracy:
-
≤±0.5nm
-
Spectrophotometer WL repeatability:
-
≤0.3nm (single direction)
-
Spectrophotometer Spectrum bandwidth:
-
0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm
-
Spectrophotometer Resolution:
-
<40%
-
Spectrophotometer Base line stability:
-
±0.004Abs/30min
-
Characteristic concentration of copper:
-
≤ 0.04μg/ml/1%
-
Detection limit of copper:
-
≤0.008μg/ml
-
Background calibration ability:
-
Greater than 30 times
-
Spectrophotometer Power supply:
-
220V 3A, 50Hz
Quick Details
-
Warranty:
-
1year
-
Size:
-
1220x770x730mm
-
Weight:
-
160kg
-
Place of Origin:
-
Zhejiang, China
-
Brand Name:
-
CHINCAN
-
Model Number:
-
AA320N
-
Wavelength Range:
-
190-900
-
Spectrophotometer WL range:
-
190-900nm
-
Spectrophotometer WL accuracy:
-
≤±0.5nm
-
Spectrophotometer WL repeatability:
-
≤0.3nm (single direction)
-
Spectrophotometer Spectrum bandwidth:
-
0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm
-
Spectrophotometer Resolution:
-
<40%
-
Spectrophotometer Base line stability:
-
±0.004Abs/30min
-
Characteristic concentration of copper:
-
≤ 0.04μg/ml/1%
-
Detection limit of copper:
-
≤0.008μg/ml
-
Background calibration ability:
-
Greater than 30 times
-
Spectrophotometer Power supply:
-
220V 3A, 50Hz
Product Description
Common Features
1
,
Build-in computer data processing and LCD display: stable and reliable with the functions of integral
holding, peakheight and area, auto zero adjusting, deuterium lamp background correction,
multi-linear and nonlinear curves fitting, various parameters and working curves displayed in screen
and report printing, etc. It is equipped with interface for externally linking PC.
2
,
Stability: Double-beam system can automatically compensate the light source drift and wavelengthdrift
caused by the variation of temperature (with the function of the eliminating the affection of
wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic
line stability.
3
,
Quickly: The cathode lamp needs not be pre-heated for long time and sample can be analyzed
immediately. It is the preferable instrument chosen by users to conduct analysis of multiple kinds
of elements and fast analysis of samples.
4
,
High precision of measurement: Gas path system is equipped with precision pressure stabilizing
and current stabilizing devices to reach stable flame and low noise. Specially designed fine light
beam passes through the flame to ensure a high precision analytical test and low characteristic
concentration
.
5
,
High energy optical path: A total reflection system is adopted to eliminate color difference in full
range. By means of chemical conversion, a round light spot of the light source becomes a long
light spot, which enters into the slit. Therefore the light flux of double beam is enhanced.
6
,
Long-life and anti-corrosive atomization system: The burner is made of new type titanium alloys,
anti-corrosive and fast thermal equilibrium. It meets the requirement of measurement sensitivity
without water-cooling.
7
,
Multi-functional analysis mode: for methods of flame absorption, flame emission, graphite furnace
atomic absorption and hydride generation.
8
,
Safe and reliable gas path system: Special devices of quick gas conversion and safety protection
can be used to analyze air-acetylene flame.
9
,
Complete set of accessories: to be supplied with the instrument and ready for use after they are
purchased.
Specifications

Standard Accessories
Oil-free air compressor
Glass Atomizer
Cu Hollow cathode lamp
Atomizer unit
Burner unit
Dust cover
Water-separating gas filter
Titanium burner---10cm
Optional Accessories
Model GA3202 HGA graphite furnace system
Hydride generator
Hollow cathode lamp
Graphite tubes
Software
Recirculating cooling water system
Technical Specification
Packaging & Shipping
Hot Searches